Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

Activated Carbon Cartridge Frame

Activated Carbon Cartridge Frame

GAS-PHASE AND ODOR FILTRATION

Activated Carbon Cartridge Frame

Activated Carbon Cartridge Frame is a supporting filter component designed for the safe and organized installation of cylindrical activated carbon filter cartridges in air handling units, duct-type filter cells and industrial gas filtration systems.

Available with galvanized or oven-painted metal body options, the cartridge frames can be configured in different dimensions to hold 4, 8, 12 or 16 Ø145 mm activated carbon cartridges. The special compression mechanism helps secure the cartridges quickly and safely.

4–16 Cartridges
Compatible with Ø145 mm
Modular Design
Activated Carbon Cartridge Frame for gas-phase and odor filtration systems

Cartridge Capacity
4–16 Pcs.
Compatible Cartridge Diameter
145 mm
Frame Dimensions
305–610 mm
Frame Depth
70 mm

What Is an Activated Carbon Cartridge Frame?

An activated carbon cartridge frame is a metal support system that secures cylindrical activated carbon filter cartridges in a defined arrangement. It also allows the airflow to pass through the cartridges in a controlled manner.

Activated carbon cartridges installed on the frame help reduce odors, volatile organic compounds and certain gas-phase contaminants through adsorption. In addition, the frame ensures correct cartridge positioning and enables easy removal and replacement during maintenance.

Available in galvanized or oven-painted metal versions, the system can be integrated into air handling units, duct-type filter housings and dedicated gas filtration cells with different cartridge quantities and installation dimensions.

Frame and Cartridge Selection Process

01
Airflow
System airflow and airflow per cartridge are determined.
02
Number of Cartridges
A 4, 8, 12 or 16-cartridge model is selected according to requirements.
03
Frame Dimensions
The width and height of the filter cell are checked.
04
Surface Finish
A galvanized or painted body is selected according to environmental conditions.
05
Installation Check
Cartridge connection, compression and sealing are checked.

Technical Specifications

Product Type Activated carbon cartridge frame Purpose Holding and securing activated carbon cartridges
Frame Material Galvanized or oven-painted metal Compatible Cartridge Type Cylindrical activated carbon cartridge
Compatible Cartridge Outside Diameter 145 mm Cartridge Capacity 4, 8, 12 or 16 pcs.
Capacity Class Standard or high capacity Nominal Frame Depth 70 mm
Mounting System Special cartridge compression mechanism Maintenance Design Removable and replaceable cartridge system
Installation Type Air handling unit or independent filter cell Application Gas filtration and odor removal

Product Coding System

Product Type Frame Capacity No. of Cartridges Dimensions
AR
Activated Carbon Cartridge Frame
P: Oven-painted metal
G: Galvanized metal
M: Standard capacity
H: High capacity
4: 4 cartridges
8: 8 cartridges
12: 12 cartridges
16: 16 cartridges
Width × Height
Example: 610 × 610 mm
Example Product Code
AR-G-H-16-610-610
Activated carbon cartridge frame – galvanized metal – high capacity – 16 cartridges – 610 × 610 mm
The cartridge quantity in the product code indicates the carrying capacity of the frame. The length, media type and gas adsorption capacity of the activated carbon cartridges must be determined separately.

Models and Dimensions

The product type prefix in the source data has been adapted to AR in accordance with the Airtes product coding system.

Frame Model Frame Type Capacity Dimensions
W × H × D
Cartridge Capacity
AR-G-H-4-305-305 Galvanized High 305 × 305 × 70 mm 4 pcs.
AR-G-H-8-305-610 Galvanized High 305 × 610 × 70 mm 8 pcs.
AR-G-H-12-508-610 Galvanized High 508 × 610 × 70 mm 12 pcs.
AR-G-H-16-610-610 Galvanized High 610 × 610 × 70 mm 16 pcs.
The dimensions in the model table refer to the supporting frame itself. Cartridge length and the total installation depth of the complete filter system must be evaluated separately.

Structural Components

Metal Support Frame
Allows activated carbon cartridges to be positioned securely and in an organized arrangement.
Cartridge Mounting Points
Allow Ø145 mm activated carbon cartridges to be attached to the frame.
Compression Mechanism
Helps apply controlled compression between the cartridges and the mounting surface.
Galvanized Surface
Provides corrosion resistance for standard industrial applications.
Oven-Painted Surface
Provides an alternative surface finish according to project conditions and visual requirements.
Modular Cartridge Design
Allows saturated cartridges to be replaced independently without replacing the supporting frame.

Compatible Activated Carbon Cartridges

The frame can be used with cylindrical activated carbon cartridges with an outside diameter of Ø145 mm. The adsorbent media inside the cartridge should be selected separately according to the target gas or odor compound.

Standard-capacity cartridge: Suitable for general gas filtration applications requiring standard carbon filling volume.
High-capacity cartridge: Can be considered for applications requiring a larger adsorbent volume.
Virgin activated carbon: Suitable for various organic vapors, solvent odors and certain VOC compounds.
Impregnated carbon: Chemically treated media can be used for certain acidic, alkaline or reactive gases.
Different cartridge lengths: Different cartridge depths can be selected according to carbon capacity and required contact time.
Special media options: Special adsorbent blends can be evaluated for processes containing multiple contaminants.

Applications

Air handling unit filter cells
Industrial odor control systems
Duct-type gas filtration units
Commercial building ventilation
Chemical storage areas
Laboratory exhaust systems
Wastewater treatment plants
Molecular contamination control

Product Advantages

Modular construction: Allows filtration capacity to be configured with different numbers of cartridges.
Easy installation: The special compression mechanism helps secure cartridges quickly.
Easy maintenance: Saturated cartridges can be replaced without replacing the supporting frame.
Different dimensions: Frame options are available from 305 × 305 mm to 610 × 610 mm.
Durable body: Galvanized or oven-painted metal construction is suitable for industrial applications.
System integration: Suitable for air handling units and dedicated filter cells.

Frame Selection Criteria

  • Total system airflow
  • Permissible airflow per cartridge
  • Required number of cartridges
  • Width and height of the filter cell
  • Outside diameter of the cartridge
  • Cartridge length and carbon volume
  • Requirement for galvanized or painted finish
  • Access space required for installation and maintenance
  • Cartridge gasket and connection geometry
  • Permissible system pressure drop

Maintenance and Cartridge Replacement

During periodic maintenance, the frame body, cartridge connection points, compression mechanism and mounting surfaces should be inspected. Loose connections, deformation and openings that may cause uncontrolled airflow should be corrected.

When replacing activated carbon cartridges, verify that all cartridges are installed in the correct direction, gasket surfaces are clean and the compression mechanism is applied evenly.

When removing used cartridges, the nature of the adsorbed chemicals should be considered. Appropriate personal protective equipment should be used, and cartridges should be disposed of according to the facility’s waste management procedures.

Frequently Asked Questions

What does an activated carbon cartridge frame do?
It secures cylindrical activated carbon cartridges within the filtration system in an organized, safe and replaceable configuration.
How many cartridges can the frame hold?
Depending on frame dimensions, models are available for 4, 8, 12 or 16 activated carbon cartridges.
Which cartridge diameter is compatible?
Standard product options are compatible with cylindrical activated carbon cartridges with an outside diameter of Ø145 mm.
Can cartridges be replaced individually?
Yes. The modular design allows cartridges to be removed and replaced individually. However, replacing all cartridges within the same filter cell at the same time may be preferred for more uniform performance.
Does the frame determine the airflow?
The frame alone does not determine airflow. Total airflow must be calculated according to cartridge quantity, cartridge length, carbon bed, permissible velocity and system pressure drop.

Technical Application Note
The dimensions and cartridge quantities shown in the tables are based on source product data. The actual system airflow and total pressure drop that can be used with the frame depend on project conditions, including cartridge type, cartridge length, activated carbon type, carbon filling density, airflow per cartridge, filter face velocity, number of cartridges, installation orientation, gasket compression, frame leakage, prefiltration level, temperature, relative humidity and system geometry. Frame and cartridge selection should not be made solely according to nominal dimensions without technical calculation.

Selecting the Right Activated Carbon Cartridge Frame for Your Application

Contact Airtes for activated carbon cartridge frame selection according to airflow, cartridge quantity, activated carbon type, cartridge length, filter cell dimensions and installation conditions.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information