Aluminum Separator HEPA Filter – MDF Frame
MDF frame HEPA filter provides high-efficiency final air filtration for hygienic air handling units and sensitive HVAC systems. It combines deep-pleated glass-fiber media with aluminum separators and a lightweight MDF frame. Therefore, it offers a practical solution for controlled indoor applications.
Aluminum separators keep the filter pleats evenly spaced. As a result, the airflow channels remain open and stable. The filter is available in E10, E11, E12, H13 and H14 classes. In addition, standard versions can operate at temperatures up to 80°C.
MDF Frame
Maximum 80°C
Aluminum Separator

Deep-Pleat Filter with MDF Frame
First, high-quality glass-fiber media creates the deep-pleat filter pack. Aluminum separators keep each pleat apart. This design increases the usable filtration area and supports stable airflow.
Next, the MDF frame provides an economical and lightweight housing. It suits standard dry indoor filter sections. Two-component polyurethane or silicone can seal the joint between the media pack and frame.
Finally, the complete filter works as a disposable element. Do not wash or rebuild the filter media. Instead, replace the complete filter when it reaches the end of its service life.
Filter Selection and Application Process
Technical Specifications
| Filter Classes | E10, E11, E12, H13 and H14 | Flange | None |
|---|---|---|---|
| Filter Media | High-quality glass fiber | Sealing Compound | Two-component polyurethane or silicone |
| Frame Type | MDF | Separator | Aluminum |
| Recommended Final Pressure Drop | 2× initial pressure drop, maximum 600 Pa | Gasket | EPDM or poured gasket |
| Maximum Operating Temperature | 80°C | Testing and Classification | EN 1822 and ISO 29463 for H13 and H14 classes |
For additional information about high-efficiency air filter classification, see the official ISO 29463-1 standard.
Product Coding System
The product code shows the filter class, frame type, grounding option, dimensions, surface protection and gasket type. Therefore, the code gives a quick summary of the selected configuration.
| Code Section | Options | Description |
|---|---|---|
| Filter Type | AR | Aluminum Separator HEPA Filter |
| Filter Class | E10 / E11 / E12 / H13 / H14 | Filter efficiency class |
| Frame | M | MDF frame |
| Grounding | SG / W | SG: Grounding included W: No grounding |
| Dimensions | Width × Height × Depth | Example: 610 × 610 × 292 mm |
| Surface Protection | FW / FC / FD / FB | FW: None FC: Clean-air side FD: Dirty-air side FB: Both sides |
| Gasket | W / P / PP / E / EE / C / CC | W: No gasket P: Poured gasket PP: Double-sided poured gasket E: EPDM gasket EE: Double-sided EPDM gasket C: Gray EPDM gasket CC: Double-sided gray EPDM gasket |
Model and Performance Data
| Filter Model | EN 1822 | ISO 29463 | Dimensions W×H×D (mm) |
Filtration Area (m²) |
Nominal Airflow (m³/h) |
Initial Pressure Drop (Pa) |
|---|---|---|---|---|---|---|
| AR-E10-M-W-305-610-292-FW-E | E10 | – | 305 × 610 × 292 | 8.5 | 1,700 | 170 |
| AR-E10-M-W-610-610-292-FW-E | E10 | – | 610 × 610 × 292 | 17.0 | 3,400 | 170 |
| AR-E11-M-W-305-610-292-FW-E | E11 | ISO 15 E | 305 × 610 × 292 | 8.5 | 1,700 | 190 |
| AR-E11-M-W-610-610-292-FW-E | E11 | ISO 15 E | 610 × 610 × 292 | 17.0 | 3,400 | 190 |
| AR-E12-M-W-305-610-292-FW-E | E12 | ISO 25 E | 305 × 610 × 292 | 8.5 | 1,500 | 270 |
| AR-E12-M-W-610-610-292-FW-E | E12 | ISO 25 E | 610 × 610 × 292 | 17.0 | 3,000 | 270 |
| AR-H13-M-W-305-610-292-FW-E | H13 | ISO 35 H | 305 × 610 × 292 | 11.0 | 1,250 | 250 |
| AR-H13-M-W-610-610-292-FW-E | H13 | ISO 35 H | 610 × 610 × 292 | 22.0 | 2,500 | 250 |
| AR-H14-M-W-305-610-292-FW-E | H14 | ISO 45 H | 305 × 610 × 292 | 11.0 | 1,100 | 250 |
| AR-H14-M-W-610-610-292-FW-E | H14 | ISO 45 H | 610 × 610 × 292 | 22.0 | 2,200 | 250 |
Structural Components
Application Areas
- Final filtration in hygienic air handling units
- Pharmaceutical production facilities
- Hospitals and healthcare buildings
- Laboratory ventilation systems
- Food and beverage production areas
- Electronics and precision manufacturing
- Controlled environments and clean-air applications
Product Advantages
- Wide range from E10 to H14
- Large filtration area with deep pleats
- Stable pleat spacing with aluminum separators
- Economical MDF frame
- Different gasket and surface-protection options
- Optional grounding
- Project-specific non-standard dimensions
Filter Selection Criteria
Maintenance and Replacement
First, monitor differential pressure across the filter regularly. Also inspect the media, aluminum separators, MDF frame and gasket. Look for tears, deformation, swelling or damaged sealing surfaces.
Next, compare the measured pressure with the clean-filter value. The recommended final pressure is about twice the initial value. However, it should not exceed 600 Pa. Airflow, hygiene and process requirements should also guide replacement timing.
Finally, replace the complete filter when necessary. Do not clean the glass-fiber media with water, compressed air, vacuum or mechanical methods.
Technical Application Note
Use MDF frame filters in dry and controlled indoor environments. Condensation, direct water contact, high humidity and chemical vapors may require another frame material. In addition, actual filter performance depends on airflow, pressure, leakage, dust load, temperature and humidity. Gasket compression, air distribution and instrument calibration also matter. Therefore, use complete project data for the final filter selection.
Select the Right HEPA Filter for Your HVAC System
Send us the filter class, airflow, existing cell dimensions and operating temperature. Also include humidity, gasket type and required initial pressure drop. We can then support technical selection and quotation preparation.
In addition, explore our industrial services for HVAC and air-filtration solutions.