Ceiling Type Filter
Ceiling Type Filter is an air filter with a large surface area. Moreover, it is used in HVAC systems to capture fine particles, to provide second or final stage filtration and to protect HEPA filters against particle load.
The filter can be produced with glass fibre media, hot-melt separators and a two-component polyurethane sealing compound. In addition, aluminium or MDF frame options are available. Standard depths of 78 mm and 150 mm cover different mounting spaces. Therefore, various pressure drop requirements can be met.
78 and 150 mm
Aluminium or MDF

What Is a Ceiling Type Filter?
A ceiling type filter is a fine filtration element. It is built by placing densely pleated glass fibre media inside a compact frame. Therefore, it suits ceiling filter housings, terminal filtration layouts and HVAC applications with limited mounting space.
The large filtration area helps to distribute the nominal air flow over the filter surface. As a result, the media is used more effectively. Furthermore, the filter can work as a second or final stage. It can also serve as a pre-filter upstream of a HEPA filter. You can review the full range on our air filter products page.
Models with 78 mm depth offer a more compact structure with a 50 mm pleat height. In contrast, 150 mm models have a 125 mm pleat height and a wider filtration area. Consequently, they can provide a lower initial pressure drop at the same nominal air flow.
Filter Selection and Application Process
Technical Specifications
| Filter standard | ISO 16890 | Filter classes | ISO ePM1, ISO ePM2.5 and ISO ePM10 |
| Filter media | Glass fibre | Frame type | Aluminium or MDF |
| Standard depth | 78 and 150 mm | Pleat height | 50–125 mm |
| Maximum operating temperature | 80°C | Face guard | Optional |
| Sealing compound | Two-component polyurethane | Separator | Hot melt |
| Gasket | Optional | Nominal air flow | 750–3,000 m³/h |
| Recommended final pressure drop | According to the EN 13053 approach, initial ΔP + 100 Pa or initial ΔP × 3, whichever is lower | ||
Product Coding System
| Product Type | Filter Class | Frame | Pleat Height | Dimensions | Face Guard | Gasket |
|---|---|---|---|---|---|---|
| AR Ceiling Type Filter |
M6 F7 F8 F9 |
A: Aluminium M: MDF |
1: 50 mm 2: 65 mm 3: 75 mm 4: 85 mm 5: 90 mm 6: 100 mm 7: 125 mm |
Width × Height × Depth Example: 610 × 610 × 78 mm |
FW: None FC: On clean side FD: On dirty side FB: On both sides |
W: None P: Poured gasket PP: Double sided poured gasket E: EPDM EE: Double sided EPDM C: Grey EPDM CC: Double sided grey EPDM |
Ceiling Type Filter / 78 mm
| Filter Model | EN 779 (withdrawn) |
ISO 16890 | Dimensions W × H × D (mm) |
Filtration Area (m²) |
Pleat Height (mm) |
Nominal Air Flow (m³/h) |
Initial Pressure Drop (Pa) |
|---|---|---|---|---|---|---|---|
| AR-M6-A-1-305-305-78-FC-P | M6 | ePM10 70% | 305 × 305 × 78 | 2.3 | 50 | 750 | 80 |
| AR-M6-A-1-305-610-78-FC-P | M6 | ePM10 70% | 305 × 610 × 78 | 4.5 | 50 | 1,500 | 80 |
| AR-M6-A-1-610-610-78-FC-P | M6 | ePM10 70% | 610 × 610 × 78 | 9 | 50 | 3,000 | 80 |
| AR-F7-A-1-305-305-78-FC-P | F7 | ePM1 55% | 305 × 305 × 78 | 2.3 | 50 | 750 | 115 |
| AR-F7-A-1-305-610-78-FC-P | F7 | ePM1 55% | 305 × 610 × 78 | 4.5 | 50 | 1,500 | 115 |
| AR-F7-A-1-610-610-78-FC-P | F7 | ePM1 55% | 610 × 610 × 78 | 9 | 50 | 3,000 | 115 |
| AR-F8-A-1-305-305-78-FC-P | F8 | ePM1 70% | 305 × 305 × 78 | 2.3 | 50 | 750 | 120 |
| AR-F8-A-1-305-610-78-FC-P | F8 | ePM1 70% | 305 × 610 × 78 | 4.5 | 50 | 1,500 | 120 |
| AR-F8-A-1-610-610-78-FC-P | F8 | ePM1 70% | 610 × 610 × 78 | 9 | 50 | 3,000 | 120 |
| AR-F9-A-1-305-305-78-FC-P | F9 | ePM1 80% | 305 × 305 × 78 | 2.3 | 50 | 750 | 145 |
| AR-F9-A-1-305-610-78-FC-P | F9 | ePM1 80% | 305 × 610 × 78 | 4.5 | 50 | 1,500 | 145 |
| AR-F9-A-1-610-610-78-FC-P | F9 | ePM1 80% | 610 × 610 × 78 | 9 | 50 | 3,000 | 145 |
Ceiling Type Filter / 150 mm
| Filter Model | EN 779 (withdrawn) |
ISO 16890 | Dimensions W × H × D (mm) |
Filtration Area (m²) |
Pleat Height (mm) |
Nominal Air Flow (m³/h) |
Initial Pressure Drop (Pa) |
|---|---|---|---|---|---|---|---|
| AR-M6-A-7-305-305-150-FC-P | M6 | ePM10 70% | 305 × 305 × 150 | 4.5 | 125 | 750 | 60 |
| AR-M6-A-7-305-610-150-FC-P | M6 | ePM10 70% | 305 × 610 × 150 | 9 | 125 | 1,500 | 60 |
| AR-M6-A-7-610-610-150-FC-P | M6 | ePM10 70% | 610 × 610 × 150 | 18 | 125 | 3,000 | 60 |
| AR-F7-A-7-305-305-150-FC-P | F7 | ePM1 55% | 305 × 305 × 150 | 4.5 | 125 | 750 | 80 |
| AR-F7-A-7-305-610-150-FC-P | F7 | ePM1 55% | 305 × 610 × 150 | 9 | 125 | 1,500 | 80 |
| AR-F7-A-7-610-610-150-FC-P | F7 | ePM1 55% | 610 × 610 × 150 | 18 | 125 | 3,000 | 80 |
| AR-F8-A-7-305-305-150-FC-P | F8 | ePM1 70% | 305 × 305 × 150 | 4.5 | 125 | 750 | 100 |
| AR-F8-A-7-305-610-150-FC-P | F8 | ePM1 70% | 305 × 610 × 150 | 9 | 125 | 1,500 | 100 |
| AR-F8-A-7-610-610-150-FC-P | F8 | ePM1 70% | 610 × 610 × 150 | 18 | 125 | 3,000 | 100 |
| AR-F9-A-7-305-305-150-FC-P | F9 | ePM1 80% | 305 × 305 × 150 | 4.5 | 125 | 750 | 130 |
| AR-F9-A-7-305-610-150-FC-P | F9 | ePM1 80% | 305 × 610 × 150 | 9 | 125 | 1,500 | 130 |
| AR-F9-A-7-610-610-150-FC-P | F9 | ePM1 80% | 610 × 610 × 150 | 18 | 125 | 3,000 | 130 |
Comparison of 78 mm and 150 mm Filters
| Comparison Criterion | 78 mm Model | 150 mm Model |
|---|---|---|
| Pleat height | 50 mm | 125 mm |
| Filtration area | 2.3–9 m² | 4.5–18 m² |
| Nominal air flow | 750–3,000 m³/h | 750–3,000 m³/h |
| Initial pressure drop | 80–145 Pa | 60–130 Pa |
| Main selection criterion | Limited mounting depth | Wider filter area and lower initial pressure |
Structural Components
Application Areas
Product Advantages
Filter Selection Criteria
- Real and nominal system air flow
- Target ISO 16890 filter class
- Width, height and depth of the filter housing
- Permitted initial and final pressure drop
- Face velocity through the filter
- Aluminium or MDF frame requirement
- Gasket and clamping system
- Face guard side and air flow direction
- Ambient temperature and relative humidity
- Dust concentration and particle characteristics
Inspection and Maintenance
The initial and operating pressure drop should be followed with a differential pressure gauge or a transmitter. Moreover, the replacement time must not be based on operating hours alone. Pressure drop, real air flow, dust load, hygiene conditions and the physical state of the filter should be evaluated together.
Glass fibre media must not be cleaned with water or compressed air unless the technical documentation clearly states that it is washable. Otherwise, such treatment can damage the media, the pleat geometry and the circumferential sealing.
Frequently Asked Questions
Selecting the Right Ceiling Type Filter for Your Project
You can contact Airtes for technical product selection. Please share the air flow, ISO 16890 class, filter size, frame type, pleat height, face guard and gasket requirements of your project. Our technical team will then propose a suitable option.