Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

Ceiling Type HEPA Filter (Knife Edge Profile)

Ceiling Type HEPA Filter (Knife Edge Profile)

H13–H14 • KNIFE EDGE PROFILE

Ceiling Type HEPA Filter (Knife Edge Profile)

The ceiling type HEPA filter is a terminal filtration solution with a knife edge profile, developed to provide final-stage particle filtration in cleanroom ceiling systems, laminar flow units and fan filter units.

The construction consists of high-quality glass fibre filter media, an aluminium frame, hot-melt pleat separators and a two-component polyurethane sealing compound. It is available in H13 and H14 filter classes with different dimensions and pleat heights.

Ceiling Type HEPA Filter Knife Edge Profile

H13–H14
HEPA Filter Classes
89 / 109 mm
Standard Filter Depths
50 / 75 mm
Pleat Height Options
80°C
Maximum Operating Temperature

What Is a Ceiling Type HEPA Filter with Knife Edge Profile?

Ceiling type HEPA filters with a knife edge profile are compact final-stage filters used inside terminal filter housings or cleanroom ceiling modules. The special profile geometry of the filter frame supports correct centring and controlled sealing within a compatible terminal system.

The glass fibre filter media is arranged in a mini-pleat configuration, increasing the filtration surface area while supporting uniform air velocity distribution. Pleat height options of 50 mm and 75 mm provide different filtration areas and initial pressure-drop alternatives at the same nominal airflow.

Actual filter performance may vary depending on airflow, face velocity, terminal housing construction, profile compatibility, mounting pressure, sealing components, test method, measuring instrument, calibration status, filter loading, humidity, temperature and process conditions.

Selection, Installation and Verification Process

1
Determination of Project Data
Cleanroom class, filter class, nominal airflow and terminal housing dimensions are determined.
2
Profile and Dimension Check
The knife edge profile, external filter dimensions, depth and terminal connection are checked.
3
Controlled Installation
The filter is installed in the terminal system without damaging the media or protective screens.
4
Testing and Validation
After installation, aerosol leak testing, airflow, velocity distribution and differential pressure checks are performed.

Technical Specifications

Filter standard EN 1822 and ISO 29463 Maximum operating temperature 80°C
Filter classes H13 and H14 Face protection Paint-coated aluminium sheet
Filter media High-quality glass fibre Gasket Poured gasket
Frame type Aluminium Sealant Two-component polyurethane
Recommended final pressure drop 2 times the initial pressure drop, maximum 600 Pa Separator Hot melt

Product Coding System

Filter Type Filter Class Frame Design Pleat Height Dimensions Face Protection Gasket
AR:
Ceiling Type HEPA Filter
Knife Edge Profile
H13
H14
A: Aluminium SM: Separated pleat design 1: 50 mm
3: 75 mm
W × H × D
Example:
610 × 610 × 89 mm
FB: Both sides P: Poured gasket
89 mm example product code:
AR-H14-A-SM-1-610-610-89-FB-P
109 mm example product code:
AR-H14-A-SM-3-610-610-109-P

Ceiling Type HEPA Filter Models – Knife Edge Profile / 89 mm

Standard H13 and H14 model options with 89 mm depth and 50 mm pleat height.

Filter Model EN 1822 ISO 29463 Dimensions
W × H × D
(mm)
Filtration Area
(m²)
Pleat Height
(mm)
Nominal Airflow
(m³/h)
Initial Pressure Drop
(Pa)
AR-H13-A-SM-1-305-305-89-FB-P H13 ISO 35 H 305 × 305 × 89 2.3 50 150 100
AR-H13-A-SM-1-305-610-89-FB-P H13 ISO 35 H 305 × 610 × 89 4.5 50 300 100
AR-H13-A-SM-1-457-457-89-FB-P H13 ISO 35 H 457 × 457 × 89 5 50 340 100
AR-H13-A-SM-1-610-610-89-FB-P H13 ISO 35 H 610 × 610 × 89 9 50 600 100
AR-H13-A-SM-1-610-915-89-FB-P H13 ISO 35 H 610 × 915 × 89 13.5 50 900 100
AR-H13-A-SM-1-610-1220-89-FB-P H13 ISO 35 H 610 × 1220 × 89 18 50 1200 100
AR-H14-A-SM-1-305-305-89-FB-P H14 ISO 45 H 305 × 305 × 89 2.4 50 150 125
AR-H14-A-SM-1-305-610-89-FB-P H14 ISO 45 H 305 × 610 × 89 4.7 50 300 125
AR-H14-A-SM-1-457-457-89-FB-P H14 ISO 45 H 457 × 457 × 89 5.3 50 340 125
AR-H14-A-SM-1-610-610-89-FB-P H14 ISO 45 H 610 × 610 × 89 9.4 50 600 125
AR-H14-A-SM-1-610-915-89-FB-P H14 ISO 45 H 610 × 915 × 89 14 50 900 125
AR-H14-A-SM-1-610-1220-89-FB-P H14 ISO 45 H 610 × 1220 × 89 18.8 50 1200 125

Ceiling Type HEPA Filter Models – Knife Edge Profile / 109 mm

Standard H13 and H14 model options with 109 mm depth and 75 mm pleat height.

Filter Model EN 1822 ISO 29463 Dimensions
W × H × D
(mm)
Filtration Area
(m²)
Pleat Height
(mm)
Nominal Airflow
(m³/h)
Initial Pressure Drop
(Pa)
AR-H13-A-SM-3-305-305-109-P H13 ISO 35 H 305 × 305 × 109 3.4 75 150 75
AR-H13-A-SM-3-305-610-109-P H13 ISO 35 H 305 × 610 × 109 6.8 75 300 75
AR-H13-A-SM-3-457-457-109-P H13 ISO 35 H 457 × 457 × 109 7.6 75 340 75
AR-H13-A-SM-3-610-610-109-P H13 ISO 35 H 610 × 610 × 109 13.5 75 600 75
AR-H13-A-SM-3-610-915-109-P H13 ISO 35 H 610 × 915 × 109 20.3 75 900 75
AR-H13-A-SM-3-610-1220-109-P H13 ISO 35 H 610 × 1220 × 109 27 75 1200 75
AR-H14-A-SM-3-305-305-109-P H14 ISO 45 H 305 × 305 × 109 3.5 75 150 90
AR-H14-A-SM-3-305-610-109-P H14 ISO 45 H 305 × 610 × 109 7.1 75 300 90
AR-H14-A-SM-3-457-457-109-P H14 ISO 45 H 457 × 457 × 109 7.9 75 340 90
AR-H14-A-SM-3-610-610-109-P H14 ISO 45 H 610 × 610 × 109 14.1 75 600 90
AR-H14-A-SM-3-610-915-109-P H14 ISO 45 H 610 × 915 × 109 21.2 75 900 90
AR-H14-A-SM-3-610-1220-109-P H14 ISO 45 H 610 × 1220 × 109 28.2 75 1200 90

Custom Size Production
Custom dimensions can be evaluated according to terminal housing, fan filter unit and project requirements.
Differential Pressure Tolerance
Initial differential pressure values may have a tolerance of ±10% depending on production and test conditions.
Coding Structure Note
The face protection segment is not shown separately in the product codes of the 109 mm models. The final face protection configuration should be confirmed at the order stage.

Structural Components

Glass Fibre Filter Media
Fine-fibre filter media used for high-efficiency H13 and H14 particle filtration.
Knife Edge Profile
Profile construction supporting correct positioning and peripheral sealing within the terminal housing.
Aluminium Frame
Provides low weight, mechanical strength and a surface suitable for cleanroom applications.
Poured Gasket
Supports controlled seating and sealing performance between the filter and connection surface.
Polyurethane Sealing
A two-component sealing compound that limits the risk of peripheral leakage between the filter pack and frame.
Hot-Melt Separator
Helps maintain controlled pleat spacing and balance airflow distribution across the filter surface.

Applications

Cleanroom ceiling systems
Laminar flow units
Fan filter units
Pharmaceutical production facilities
Hospitals and operating theatres
Microelectronics production
Food production areas
Biotechnology laboratories

Product Advantages

  • H13 and H14 filter class options
  • 89 mm and 109 mm depth alternatives
  • 50 mm and 75 mm pleat height options
  • Mini-pleat structure with high filtration area
  • Compact design for fan filter units and terminal housings
  • Filter options available with individual test certificates
  • Pleat geometry supporting optimum air velocity distribution
  • Custom size production capability
  • Aluminium frame and face protection sheets
  • Construction suitable for leak-tightness verification with correct installation and testing

Filter Selection Criteria

  • Cleanroom class and permissible particle level of the process
  • H13 or H14 filter class requirement
  • Actual airflow per filter
  • 89 mm or 109 mm filter depth
  • 50 mm or 75 mm pleat height
  • Knife edge profile compatibility of the terminal housing
  • External filter dimensions and installation tolerances
  • Initial pressure drop and available fan static pressure
  • Face protection sheet requirement
  • Pre-filtration level, dust load, humidity, temperature and process conditions

Inspection, Maintenance and Replacement

Differential Pressure Monitoring
The initial and operating differential pressure values of the filter should be monitored regularly.
Visual Inspection
The protection sheet, frame, filter media and gasket surface should be checked for damage or deformation.
Filter Replacement
The filter should be replaced when the final pressure drop is reached, when test results are unacceptable or when physical damage is detected.
Revalidation
After filter replacement, aerosol leak testing, airflow measurement and required cleanroom measurements should be repeated.

Technical application note
The nominal airflow rates and initial pressure drops stated in the tables are product values under standard test conditions. Actual operating performance may vary depending on air density, face velocity, terminal housing geometry, knife edge profile compatibility, mounting pressure, sealing components, aerosol type, test area, measuring instrument, calibration status, filter loading, humidity, temperature and process conditions. Final selection should be made according to project calculations and validation requirements.

HEPA Filter Selection with Knife Edge Profile

Contact Airtes for the selection of a ceiling type HEPA filter suitable for your cleanroom class, airflow, terminal housing dimensions and pressure-drop criteria.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information