Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

Ceiling-Type HEPA Filter with Gel Seal

Ceiling-Type HEPA Filter with Gel Seal

H13 – H14 ABSOLUTE FILTRATION

Ceiling-Type HEPA Filter with Gel Seal

The Ceiling-Type HEPA Filter with Gel Seal is an H13 and H14 class absolute filter with an aluminium frame, used for final-stage filtration in cleanrooms, laminar airflow units and controlled areas requiring high air purity. The liquid gel sealing system supports the formation of a controlled and continuous sealing structure at the interface between the filter and the terminal housing.

Ceiling-Type HEPA Filter with Gel Seal

FILTER STANDARD
EN 1822 / ISO 29463
FILTER CLASS
H13 – H14
SEALING
Liquid Gel Seal
MAXIMUM TEMPERATURE
80°C

What Is a HEPA Filter with Gel Seal?

In HEPA filters with gel seals, the continuous gel channel on the filter frame mates with the knife-edge counterpart in the terminal filter housing. As the knife-edge profile enters the gel in a controlled manner, a continuous sealing line is formed around the filter perimeter.

High-quality glass fibre filter media is fixed in a uniform mini-pleat geometry using a hot-melt separator system. Together with the aluminium frame, two-component polyurethane sealing compound and face protection plates, it provides a compact and durable terminal filtration structure.

Filtration and Sealing Process

01
Filter Installation
The filter is correctly positioned in the mounting recess of the terminal housing.
02
Gel Channel Engagement
The terminal housing knife-edge profile enters the gel channel in a controlled manner.
03
Perimeter Sealing
The gel forms a continuous and flexible sealing line around the filter perimeter.
04
Particle Filtration
Air passes through H13 or H14 class glass fibre filter media.
05
Controlled Air Supply
Filtered air is supplied to the cleanroom or laminar airflow zone.

Technical Specifications

Filter Standard EN 1822 and ISO 29463 Maximum Operating Temperature 80°C
Filter Class H13 and H14 Face Protection Paint-coated aluminium sheet
Filter Media High-quality glass fibre Gasket Liquid gel seal
Frame Type Aluminium Sealing Compound Two-component polyurethane
Recommended Final Pressure Drop 2 times the initial pressure drop, maximum 600 Pa Separator Hot melt

Flexible Gel Structure
The gel material helps retain its elastic sealing characteristics under suitable storage and operating conditions.
Individual Testing Option
Filters can be supplied with individual testing and certification options based on EN 1822 or ISO 29463.
Uniform Air Distribution
The uniform mini-pleat geometry supports balanced air velocity distribution across the filter surface.
Wide Product Range
Product depth options of 71, 80, 91, 104, 128 and 150 mm are available.

Product Coding System

Filter Type Filter Class Frame Pleat Height Design Dimensions Face Protection Gasket
AR:
Ceiling-Type
HEPA Filter with Gel Seal
H13
H14
A: Aluminium N: 42 mm
J: 55 mm
M: 68 mm
L: 92 mm
X: 115 mm
J: Gel type Width × Height × Depth
Example: 610 × 610 × 71 mm
FB: Both sides G: Gel seal
Coding example:
AR-H14-A-L-J-610-610-128-FB-G

71 mm Depth – 42 mm Pleat Height

Compact H13 and H14 class ceiling-type HEPA filter models with gel seals.

Filter Model EN 1822 ISO 29463 Dimensions W×H×D (mm) Filter Area (m²) Pleat Height (mm) Nominal Airflow (m³/h) Initial Pressure Drop (Pa)
AR-H13-A-N-J-305-305-71-FB-G H13 ISO 35 H 305×305×71 2.3 42 150 100
AR-H13-A-N-J-305-610-71-FB-G H13 ISO 35 H 305×610×71 4.5 42 300 100
AR-H13-A-N-J-457-457-71-FB-G H13 ISO 35 H 457×457×71 5 42 340 100
AR-H13-A-N-J-610-610-71-FB-G H13 ISO 35 H 610×610×71 9 42 600 100
AR-H13-A-N-J-610-915-71-FB-G H13 ISO 35 H 610×915×71 13.5 42 900 100
AR-H13-A-N-J-610-1220-71-FB-G H13 ISO 35 H 610×1220×71 18 42 1200 100
AR-H13-A-N-J-762-915-71-FB-G H13 ISO 35 H 762×915×71 16.9 42 1130 100
AR-H13-A-N-J-915-915-71-FB-G H13 ISO 35 H 915×915×71 20.3 42 1350 100
AR-H14-A-N-J-305-305-71-FB-G H14 ISO 45 H 305×305×71 2.4 42 150 125
AR-H14-A-N-J-305-610-71-FB-G H14 ISO 45 H 305×610×71 4.7 42 300 125
AR-H14-A-N-J-457-457-71-FB-G H14 ISO 45 H 457×457×71 5.3 42 340 125
AR-H14-A-N-J-610-610-71-FB-G H14 ISO 45 H 610×610×71 9.4 42 600 125
AR-H14-A-N-J-610-915-71-FB-G H14 ISO 45 H 610×915×71 14 42 900 125
AR-H14-A-N-J-610-1220-71-FB-G H14 ISO 45 H 610×1220×71 18.8 42 1200 125
AR-H14-A-N-J-762-915-71-FB-G H14 ISO 45 H 762×915×71 17.6 42 1130 125
AR-H14-A-N-J-915-915-71-FB-G H14 ISO 45 H 915×915×71 21.2 42 1350 125

80 mm Depth – 42 mm Pleat Height

Filter Model EN 1822 ISO 29463 Dimensions W×H×D (mm) Filter Area (m²) Pleat Height (mm) Nominal Airflow (m³/h) Initial Pressure Drop (Pa)
AR-H13-A-N-J-305-305-80-FB-G H13 ISO 35 H 305×305×80 2.3 42 150 100
AR-H13-A-N-J-305-610-80-FB-G H13 ISO 35 H 305×610×80 4.5 42 300 100
AR-H13-A-N-J-457-457-80-FB-G H13 ISO 35 H 457×457×80 5 42 340 100
AR-H13-A-N-J-610-610-80-FB-G H13 ISO 35 H 610×610×80 9 42 600 100
AR-H13-A-N-J-610-915-80-FB-G H13 ISO 35 H 610×915×80 13.5 42 900 100
AR-H13-A-N-J-610-1220-80-FB-G H13 ISO 35 H 610×1220×80 18 42 1200 100
AR-H13-A-N-J-762-915-80-FB-G H13 ISO 35 H 762×915×80 16.9 42 1130 100
AR-H13-A-N-J-915-915-80-FB-G H13 ISO 35 H 915×915×80 20.3 42 1350 100
AR-H14-A-N-J-305-305-80-FB-G H14 ISO 45 H 305×305×80 2.4 42 150 125
AR-H14-A-N-J-305-610-80-FB-G H14 ISO 45 H 305×610×80 4.7 42 300 125
AR-H14-A-N-J-457-457-80-FB-G H14 ISO 45 H 457×457×80 5.3 42 340 125
AR-H14-A-N-J-610-610-80-FB-G H14 ISO 45 H 610×610×80 9.4 42 600 125
AR-H14-A-N-J-610-915-80-FB-G H14 ISO 45 H 610×915×80 14 42 900 125
AR-H14-A-N-J-610-1220-80-FB-G H14 ISO 45 H 610×1220×80 18.8 42 1200 125
AR-H14-A-N-J-762-915-80-FB-G H14 ISO 45 H 762×915×80 17.6 42 1130 125
AR-H14-A-N-J-915-915-80-FB-G H14 ISO 45 H 915×915×80 21.2 42 1350 125

91 mm Depth – 55 mm Pleat Height

Filter Model EN 1822 ISO 29463 Dimensions W×H×D (mm) Filter Area (m²) Pleat Height (mm) Nominal Airflow (m³/h) Initial Pressure Drop (Pa)
AR-H13-A-J-J-305-305-91-FB-G H13 ISO 35 H 305×305×91 2.7 55 150 90
AR-H13-A-J-J-305-610-91-FB-G H13 ISO 35 H 305×610×91 5.4 55 300 90
AR-H13-A-J-J-457-457-91-FB-G H13 ISO 35 H 457×457×91 6 55 340 90
AR-H13-A-J-J-610-610-91-FB-G H13 ISO 35 H 610×610×91 10.7 55 600 90
AR-H13-A-J-J-610-915-91-FB-G H13 ISO 35 H 610×915×91 16 55 900 90
AR-H13-A-J-J-610-1220-91-FB-G H13 ISO 35 H 610×1220×91 21.4 55 1200 90
AR-H13-A-J-J-762-915-91-FB-G H13 ISO 35 H 762×915×91 20 55 1130 90
AR-H13-A-J-J-915-915-91-FB-G H13 ISO 35 H 915×915×91 24 55 1350 90
AR-H14-A-J-J-305-305-91-FB-G H14 ISO 45 H 305×305×91 2.8 55 150 115
AR-H14-A-J-J-305-610-91-FB-G H14 ISO 45 H 305×610×91 5.7 55 300 115
AR-H14-A-J-J-457-457-91-FB-G H14 ISO 45 H 457×457×91 6.3 55 340 115
AR-H14-A-J-J-610-610-91-FB-G H14 ISO 45 H 610×610×91 11.3 55 600 115
AR-H14-A-J-J-610-915-91-FB-G H14 ISO 45 H 610×915×91 17 55 900 115
AR-H14-A-J-J-610-1220-91-FB-G H14 ISO 45 H 610×1220×91 22.6 55 1200 115
AR-H14-A-J-J-762-915-91-FB-G H14 ISO 45 H 762×915×91 21.6 55 1130 115
AR-H14-A-J-J-915-915-91-FB-G H14 ISO 45 H 915×915×91 25.5 55 1350 115

104 mm Depth – 68 mm Pleat Height

Filter Model EN 1822 ISO 29463 Dimensions W×H×D (mm) Filter Area (m²) Pleat Height (mm) Nominal Airflow (m³/h) Initial Pressure Drop (Pa)
AR-H13-A-M-J-305-305-104-FB-G H13 ISO 35 H 305×305×104 3 68 150 85
AR-H13-A-M-J-305-610-104-FB-G H13 ISO 35 H 305×610×104 6.2 68 300 85
AR-H13-A-M-J-457-457-104-FB-G H13 ISO 35 H 457×457×104 7 68 340 85
AR-H13-A-M-J-610-610-104-FB-G H13 ISO 35 H 610×610×104 12.4 68 600 85
AR-H13-A-M-J-610-915-104-FB-G H13 ISO 35 H 610×915×104 18.6 68 900 85
AR-H13-A-M-J-610-1220-104-FB-G H13 ISO 35 H 610×1220×104 24.9 68 1200 85
AR-H13-A-M-J-762-915-104-FB-G H13 ISO 35 H 762×915×104 23.3 68 1130 85
AR-H13-A-M-J-915-915-104-FB-G H13 ISO 35 H 915×915×104 28 68 1350 85
AR-H14-A-M-J-305-305-104-FB-G H14 ISO 45 H 305×305×104 3.3 68 150 100
AR-H14-A-M-J-305-610-104-FB-G H14 ISO 45 H 305×610×104 6.5 68 300 100
AR-H14-A-M-J-457-457-104-FB-G H14 ISO 45 H 457×457×104 7.4 68 340 100
AR-H14-A-M-J-610-610-104-FB-G H14 ISO 45 H 610×610×104 13 68 600 100
AR-H14-A-M-J-610-915-104-FB-G H14 ISO 45 H 610×915×104 19.6 68 900 100
AR-H14-A-M-J-610-1220-104-FB-G H14 ISO 45 H 610×1220×104 26.2 68 1200 100
AR-H14-A-M-J-762-915-104-FB-G H14 ISO 45 H 762×915×104 24.5 68 1130 100
AR-H14-A-M-J-915-915-104-FB-G H14 ISO 45 H 915×915×104 29.5 68 1350 100

128 mm Depth – 92 mm Pleat Height

Filter Model EN 1822 ISO 29463 Dimensions W×H×D (mm) Filter Area (m²) Pleat Height (mm) Nominal Airflow (m³/h) Initial Pressure Drop (Pa)
AR-H13-A-L-J-305-305-128-FB-G H13 ISO 35 H 305×305×128 4.5 92 150 65
AR-H13-A-L-J-305-610-128-FB-G H13 ISO 35 H 305×610×128 9 92 300 65
AR-H13-A-L-J-457-457-128-FB-G H13 ISO 35 H 457×457×128 10 92 340 65
AR-H13-A-L-J-610-610-128-FB-G H13 ISO 35 H 610×610×128 18 92 600 65
AR-H13-A-L-J-610-915-128-FB-G H13 ISO 35 H 610×915×128 27 92 900 65
AR-H13-A-L-J-610-1220-128-FB-G H13 ISO 35 H 610×1220×128 36 92 1200 65
AR-H13-A-L-J-762-915-128-FB-G H13 ISO 35 H 762×915×128 33.4 92 1130 65
AR-H13-A-L-J-915-915-128-FB-G H13 ISO 35 H 915×915×128 40.5 92 1350 65
AR-H14-A-L-J-305-305-128-FB-G H14 ISO 45 H 305×305×128 4.7 92 150 80
AR-H14-A-L-J-305-610-128-FB-G H14 ISO 45 H 305×610×128 9.4 92 300 80
AR-H14-A-L-J-457-457-128-FB-G H14 ISO 45 H 457×457×128 10.5 92 340 80
AR-H14-A-L-J-610-610-128-FB-G H14 ISO 45 H 610×610×128 18.8 92 600 80
AR-H14-A-L-J-610-915-128-FB-G H14 ISO 45 H 610×915×128 28.2 92 900 80
AR-H14-A-L-J-610-1220-128-FB-G H14 ISO 45 H 610×1220×128 37.6 92 1200 80
AR-H14-A-L-J-762-915-128-FB-G H14 ISO 45 H 762×915×128 35.2 92 1130 80
AR-H14-A-L-J-915-915-128-FB-G H14 ISO 45 H 915×915×128 42.3 92 1350 80

150 mm Depth – 115 mm Pleat Height

Models for applications requiring a large filtration area and low initial pressure drop.

Filter Model EN 1822 ISO 29463 Dimensions W×H×D (mm) Filter Area (m²) Pleat Height (mm) Nominal Airflow (m³/h) Initial Pressure Drop (Pa)
AR-H13-A-X-J-305-305-150-FB-G H13 ISO 35 H 305×305×150 5.6 115 150 55
AR-H13-A-X-J-305-610-150-FB-G H13 ISO 35 H 305×610×150 11.3 115 300 55
AR-H13-A-X-J-457-457-150-FB-G H13 ISO 35 H 457×457×150 12.6 115 340 55
AR-H13-A-X-J-610-610-150-FB-G H13 ISO 35 H 610×610×150 22.5 115 600 55
AR-H13-A-X-J-610-915-150-FB-G H13 ISO 35 H 610×915×150 33.8 115 900 55
AR-H13-A-X-J-610-1220-150-FB-G H13 ISO 35 H 610×1220×150 45 115 1200 55
AR-H14-A-X-J-305-305-150-FB-G H14 ISO 45 H 305×305×150 5.9 115 150 70
AR-H14-A-X-J-305-610-150-FB-G H14 ISO 45 H 305×610×150 11.8 115 300 70
AR-H14-A-X-J-457-457-150-FB-G H14 ISO 45 H 457×457×150 13.2 115 340 70
AR-H14-A-X-J-610-610-150-FB-G H14 ISO 45 H 610×610×150 23.5 115 600 70
AR-H14-A-X-J-610-915-150-FB-G H14 ISO 45 H 610×915×150 35.3 115 900 70
AR-H14-A-X-J-610-1220-150-FB-G H14 ISO 45 H 610×1220×150 47 115 1200 70

Production and tolerance note:
Custom dimensions can be manufactured. Initial differential pressure tolerance is ±10%.

Application Areas

Cleanrooms
Final-stage filtration in pharmaceutical, biotechnology, electronics and precision manufacturing cleanrooms.
LAF Units
Laminar airflow cabinets, workstations and clean-air modules.
Pharmaceutical Production Facilities
Sterile production, filling, packaging and controlled process areas.
Hospitals
Operating theatres, isolation rooms, intensive care units and controlled healthcare areas.
Microelectronics
Electronics and precision component production where particle control is critical.
Food and Beverage
Final-stage air filtration in hygienic processing, filling and packaging areas.

Product Advantages

  • H13 and H14 filter class options
  • Continuous liquid gel sealing channel
  • Compact aluminium-frame design
  • High-quality glass fibre filter media
  • Different pleat heights and product depths
  • Double-sided face protection plates
  • Individual testing and certification option
  • Custom-size manufacturing capability

Filter Selection Criteria

  • Required H13 or H14 filter class
  • Compatibility of terminal housing and knife-edge profile
  • Filter width, height and depth
  • Nominal airflow and face velocity
  • Initial and allowable final pressure drop
  • Cleanroom class and process conditions
  • Efficiency of the prefiltration stage
  • On-site integrity and leak tests

Installation, Inspection and Replacement

Pre-Installation Inspection
The frame, filter media, gel channel and face protection plates should be checked for physical damage.
Protection of the Gel Channel
Cutting, sharp or contaminating tools must not contact the gel channel, and the gel surface should be kept clean.
On-Site Verification
After installation, aerosol integrity testing, sealing inspection and airflow verification should be performed where required.
Filter Replacement
The filter should be replaced based on the final pressure limit, integrity test result, process risk or validation plan.

Technical Application Note

Actual on-site HEPA filter performance may vary depending on the filter class, individual test result, terminal housing geometry, knife-edge profile, condition of the gel channel, compression and installation accuracy, airflow, face velocity, pressure drop, prefiltration, temperature, humidity, aerosol test method and process conditions. Filter selection should not be based solely on nominal dimensions; mechanical compatibility with the terminal housing and on-site sealing verification should be evaluated together.

Let Us Select the Right HEPA Filter for Your Project

Contact Airtes for technical product selection and quotation based on filter class, airflow, terminal housing dimensions, gel channel configuration, pressure drop and testing requirements.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information