Clean Room Panels
Sandwich Panel Solutions for Laboratories, Pharmaceutical, Food, Electronics and Hygienic Production Areas
Clean Room Panels are specialised sandwich panel systems used to maintain controlled conditions in hygienic production areas, simplify surface cleaning, reduce air leakage and create modular clean room structures.
Manufactured with core options such as rock wool, glass magnesium, magnesium oxysulfide, aluminium honeycomb, paper honeycomb and EPS, clean room panels can be configured for each project with antistatic, antibacterial, stainless-steel or pre-painted steel surfaces.

50 / 75 / 100 mm Thickness
Available in different thicknesses for clean room wall and partition applications.
Multiple Core Options
Offers rock wool, magnesium oxysulfide, glass magnesium, EPS and honeycomb-filled panel options.
Antistatic / Antibacterial Surface
Can be supplied with surface coatings and hygienic-use options suitable for clean room conditions.
What Is a Clean Room Panel?
A clean room panel is a sandwich panel system used to form wall, partition and ceiling surfaces in controlled environments. Its two faces are metal-clad, while its core can be selected for different performance requirements.
In hygienic areas, panel surfaces must be easy to clean, smooth, durable and airtight. For this reason, clean room panels are preferred as modular building elements in pharmaceutical, biotechnology, electronics, food, laboratory, medical production, hospital support and precision-manufacturing facilities.
Clean Room Panel System Application Principle
Panel Selection
The core material is selected according to fire resistance, sound insulation, weight, hygiene and mechanical-strength requirements.
Modular Installation
Panels are installed according to the clean room layout together with wall, ceiling, door and window details.
Airtight Joints
Corner, door, window and panel joints are detailed to reduce air leakage and dust accumulation.
Hygienic Use
Smooth surfaces are used to simplify cleaning and disinfection processes.
Key Technical Features
50 / 75 / 100 mm options.
Width options: 980 / 1180 mm for manual production and 950 / 1150 mm for machine production.
Pre-painted steel or stainless-steel surface options.
Z / AZ / AZM coating alternatives.
PE / PVDF / HDP / SMP paint options.
Antistatic and antibacterial surface functions are available.
Manual-Production Clean Room Panel Technical Table
| Thickness | Width | Core Material | Face / Coating / Function |
|---|---|---|---|
| 50 / 75 / 100 mm | 980 / 1180 mm | Rock wool | Pre-painted steel or stainless steel Coating: Z / AZ / AZM Paint: PE / PVDF / HDP / SMP Function: antistatik / antibakteriyel |
| Single-sided glass-magnesium rock wool | |||
| Double-sided glass-magnesium rock wool | |||
| Single-sided gypsum rock wool | |||
| Double-sided gypsum rock wool | |||
| Magnesium oxysulfide | |||
| Silica rock | |||
| EPS | |||
| Glass-magnesium grid | |||
| Paper honeycomb | |||
| Aluminium honeycomb |
Machine-Production Clean Room Panel Technical Table
| Thickness | Width | Core Material | Face / Coating / Function |
|---|---|---|---|
| 50 / 75 / 100 mm | 950 / 1150 mm | Rock wool | Pre-painted steel or stainless steel Coating: Z / AZ / AZM Paint: PE / PVDF / HDP / SMP Function: antistatik / antibakteriyel |
| Magnesium oxysulfide | |||
| Silica rock | |||
| EPS | |||
| Paper honeycomb | |||
| Glass-magnesium grid |
Panel Performance Comparison Table
| Feature | Taş Yünü Panel | Mgo + Taş Yünü Panel | Alüminyum Petek Panel |
|---|---|---|---|
| Weight | 15 – 16 kg/m² | 17 – 23 kg/m² | 10 – 15 kg/m² |
| Core density | 100 – 120 kg/m³ | – | – |
| Sound insulation | 25 dB | 30 dB | 18 dB |
| Bending load capacity | 1.1 kN/m² | 1.25 kN/m² | 1.0 kN/m² |
| Water resistance | ≥ 98% | – | – |
| Fire resistance | 30 min | 60 min | 41 min |
Note: Panel weights are assessed on the basis of a 50 mm thickness.
Core Material Options
Complementary Clean Room Components
Its smooth, seamless corner construction reduces air leakage and dust accumulation at joints, making cleaning and disinfection easier.
Available in steel, stainless steel, pre-painted steel or melamine-resin door options. The door core can use flame-retardant paper honeycomb or aluminium honeycomb material.
Can be integrated into clean room wall panels with single- or double-glazed windows in square-cornered or rounded-corner designs.
Clean Room Window Technical Table
| Feature | Option / Description |
|---|---|
| Glass | Tempered glass, fire-resistant glass, privacy glass |
| Window frame and cover plate | Aluminium-alloy profiles |
| Window thickness | 50 / 75 / 100 mm |
Applications
Advantages of Clean Room Panels
Application Note
When selecting a clean room panel, evaluate the clean room classification, hygiene requirements, fire resistance, panel thickness, face material, core material, panel-joint detail, door/window integration, airtightness, resistance to disinfection chemicals and mechanical installation conditions together.
Get Technical Support for Clean Room Panel Selection
A clean room panel system should be engineered according to panel thickness, core material, fire resistance, surface coating, door/window details and hygienic-area requirements.
Request a project-specific technical assessment for clean room panels for pharmaceutical, food, electronics, laboratory, hospital and hygienic production areas.
“`