Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

High Efficiency Rigid Filter with Aluminum Frame

High Efficiency Rigid Filter with Aluminum Frame

HIGH-EFFICIENCY FILTRATION WITH ALUMINUM FRAME

High Efficiency Rigid Filter (Aluminum Frame)

High efficiency rigid filter with aluminum frame provides a large filtration area within a lightweight and durable body. It is a compact final-stage air filter for air handling units, HVAC equipment and cleanroom ventilation systems. Available efficiency classes include E10, E11, E12, H13 and H14.

Glass-fiber filter media, hot-melt separators and a two-component polyurethane sealing compound create a large effective filtration surface within compact dimensions. In addition, the aluminum frame reduces overall filter weight and makes installation and replacement easier.

E10–H14
Aluminum Frame
100 and 130 mm
Maximum 80°C

✆CONTACT US

High efficiency rigid filter with aluminum frame E10 to H14

Filter Classes
E10–E12 / H13–H14
Frame Construction
Aluminum
Nominal Airflow
300–2,500 m³/h
Standard Depths
100 and 130 mm

Rigid Filter Construction with Aluminum Frame

High efficiency rigid filters are manufactured by securing mini-pleated glass-fiber filter packs with a large surface area inside an aluminum frame. The rigid body helps the filter pack maintain its shape under airflow and operating pressure.

Compared with conventional metal bodies, the aluminum frame offers low weight and good corrosion resistance. Therefore, it provides an advantage where filters are changed frequently, service access is limited or total filter weight is important.

Products can be supplied with standard depths of 100 or 130 mm. The nominal values in the model performance table refer to standard models with 130 mm depth and a 25 mm flange.

Filter Selection and Application Process

01
Filter Class
Select E10, E11, E12, H13 or H14 according to the target particle efficiency and process requirements.
02
Airflow and Pressure
Check operating airflow, initial differential pressure and available fan pressure together.
03
Flange and Gasket
Evaluate 20 or 25 mm flange options together with EPDM, gray EPDM and double-sided gasket alternatives.
04
Installation Check
Check the filter housing, clamping mechanism, gasket surface and differential pressure after installation.

Technical Specifications

Filter Standard EN 1822 and ISO 29463 Maximum Operating Temperature 80°C
Filter Classes E10, E11, E12, H13 and H14 Depth 100 and 130 mm
Filter Media Glass fiber Surface Protection Optional
Frame Type Aluminum Sealing Compound Two-component polyurethane
Recommended Final Pressure Drop 2× initial pressure drop, maximum 600 Pa Separator Hot-melt adhesive

For additional information about international filtration standards, visit the official ISO website.

Product Coding System

The product code identifies the filter type, filter class, frame material, flange size, external dimensions, surface protection and gasket option.

Example product code: AR-H14-A-25-592-592-130-FC-E
Code Section Options Description
Filter Type AR High Efficiency Rigid Filter with aluminum frame
Filter Class E10 / E11 / E12 / H13 / H14 Filter efficiency class according to EN 1822 and ISO 29463
Frame A Aluminum frame
Flange 20 / 25 20 or 25 mm flange size
Dimensions Width × Height × Depth Example: 592 × 592 × 130 mm
Surface Protection FW / FC / FD / FB FW: No surface protection
FC: Clean-air side
FD: Dirty-air side
FB: Both sides
Gasket W / E / EE / C / CC W: No gasket
E: EPDM gasket
EE: Double-sided EPDM gasket
C: Gray EPDM gasket
CC: Double-sided gray EPDM gasket

Filter Models and Performance Data

Filter Model EN 1822 ISO 29463 Dimensions W×H×D
(mm)
Filtration Area
(m²)
Nominal Airflow
(m³/h)
Initial Pressure Drop
(Pa)
AR-E10-A-25-287-287-130-FW-W E10 – 287 × 287 × 130 3.2 625 190
AR-E10-A-25-287-592-130-FW-W E10 – 287 × 592 × 130 6.5 1,250 190
AR-E10-A-25-592-592-130-FW-W E10 – 592 × 592 × 130 13 2,500 190
AR-E11-A-25-287-287-130-FW-W E11 ISO 15 E 287 × 287 × 130 3.2 500 210
AR-E11-A-25-287-592-130-FW-W E11 ISO 15 E 287 × 592 × 130 6.5 1,000 210
AR-E11-A-25-592-592-130-FW-W E11 ISO 15 E 592 × 592 × 130 13 2,000 210
AR-E12-A-25-287-287-130-FW-W E12 ISO 25 E 287 × 287 × 130 3.2 375 250
AR-E12-A-25-287-592-130-FW-W E12 ISO 25 E 287 × 592 × 130 6.5 750 250
AR-E12-A-25-592-592-130-FW-W E12 ISO 25 E 592 × 592 × 130 13 1,500 250
AR-H13-A-25-287-287-130-FC-E H13 ISO 35 H 287 × 287 × 130 3.2 375 270
AR-H13-A-25-287-592-130-FC-E H13 ISO 35 H 287 × 592 × 130 6.5 750 270
AR-H13-A-25-592-592-130-FC-E H13 ISO 35 H 592 × 592 × 130 13 1,500 270
AR-H14-A-25-287-287-130-FC-E H14 ISO 45 H 287 × 287 × 130 3.2 300 270
AR-H14-A-25-287-592-130-FC-E H14 ISO 45 H 287 × 592 × 130 6.5 600 270
AR-H14-A-25-592-592-130-FC-E H14 ISO 45 H 592 × 592 × 130 13 1,200 270
Note: Custom dimensions are available. Initial differential-pressure tolerance is ±10%. The performance table shows standard models with 130 mm depth and a 25 mm flange.

Structural Components

Glass-Fiber Filter Media
Fine-fiber filter media used for high-efficiency classes from E10 to H14.
Aluminum Frame
A supporting body that provides low weight, mechanical rigidity and corrosion resistance.
Polyurethane Sealing
Two-component polyurethane seals the connection between the filter pack and aluminum frame.
Hot-Melt Separator
Maintains regular spacing between mini-pleats and helps preserve airflow channels.
Optional Surface Protection
Protective surfaces can be applied on the clean-air side, dirty-air side or both sides of the filter media.

Application Areas

  • Final filtration in air handling units
  • HVAC equipment
  • Cleanroom ventilation systems
  • Pharmaceutical production and laboratories
  • Hospitals and healthcare facilities
  • Industrial systems requiring compact high-efficiency filtration

Product Advantages

  • Large filtration area
  • Lightweight aluminum frame
  • Compact and rigid body
  • E10, E11, E12, H13 and H14 options
  • Different gasket and surface-protection alternatives
  • Custom-size manufacturing option

Filter Selection Criteria

Filter Class
Select E10–H14 according to the required particle-retention efficiency and clean-area classification.
Nominal Airflow
Compare actual operating airflow with the nominal airflow shown in the model table.
Filter Depth
Choose 100 or 130 mm depth according to the existing filter cell and available installation space.
Flange Size
The 20 or 25 mm flange must be compatible with the existing housing and clamping mechanism.
Gasket Selection
Select gasket type and position according to the contact surface and airflow direction.
Initial Pressure Drop
Consider clean-filter initial differential pressure when evaluating fan capacity and energy consumption.

Maintenance and Replacement

Monitor differential pressure across the filter regularly. During periodic maintenance, inspect the aluminum frame, filter media, surface protection, gasket and seating inside the filter housing.

The recommended final pressure drop is approximately twice the clean-filter initial value and should not exceed 600 Pa. Determine replacement intervals by considering differential pressure, air quality, fan energy consumption and process conditions together.

Do not clean the filter media with compressed air, wash it or subject the filter pack to mechanical impact. Remove and dispose of used filters according to facility procedures.

Technical Application Note

The filtration area, nominal airflow and initial pressure-drop values in the table represent standard product data. Actual filter performance can vary depending on installation, filter-cell leakage, test conditions, actual airflow, system pressure, instrument calibration, dust load, relative humidity, temperature, filter loading and airflow distribution. Therefore, individual testing and certification requirements for H13 and H14 filters should be clearly defined before ordering.

Select the Right Rigid Filter for Your Project

Share the required filter class, nominal airflow, filter-cell dimensions, flange type, gasket type, surface protection and operating conditions to receive technical selection and quotation support.

You can also review our industrial HVAC and filtration services.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information