Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

High Efficiency Rigid Filter

High Efficiency Rigid Filter

HIGH-EFFICIENCY FILTRATION WITH PLASTIC FRAME

High Efficiency Rigid Filter (Plastic Frame)

High efficiency rigid filter combines a large glass-fiber filtration area with a lightweight and rigid polystyrene frame. It provides compact final-stage air filtration for HVAC equipment, air handling units and cleanroom ventilation systems. Available efficiency classes include E10, E11, E12, H13 and H14.

The polystyrene frame reduces overall weight and removes the need for a metal outer frame. Meanwhile, mini-pleated glass-fiber media and hot-melt separators create a large filtration surface within compact dimensions. A two-component polyurethane compound seals the filter pack to the frame.

E10–H14
Polystyrene Frame
130 mm Depth
Maximum 80°C

✆CONTACT US

High efficiency rigid filter with plastic frame E10 to H14

Filter Classes
E10–E12 / H13–H14
Frame Material
Polystyrene
Nominal Airflow
300–2,500 m³/h
Filter Depth
130 mm

Rigid Filter Construction with Plastic Frame

First, the mini-pleated glass-fiber media creates a large filtration area. Hot-melt separators maintain regular spacing between the pleats. As a result, airflow can spread more evenly across the filter surface.

The polystyrene frame offers low weight and good corrosion resistance. Therefore, installation and filter replacement become easier. In addition, the plastic body helps avoid surface oxidation associated with metal frames in humid environments.

The product group uses a 130 mm filter depth and a 25 mm flange. Several surface-protection and gasket options are available. Standard dimensions include 287 × 287 mm, 287 × 592 mm and 592 × 592 mm.

Filter Selection and Application Process

01
Filter Class
First, select E10, E11, E12, H13 or H14 according to the required particle efficiency and process conditions.
02
Airflow Check
Next, compare the actual airflow per filter with nominal airflow and initial differential pressure.
03
Gasket Selection
Then, select poured, EPDM or gray EPDM gaskets according to the housing and sealing surface.
04
Installation and Check
Finally, check the housing, flange, gasket contact, clamping mechanism and differential pressure after installation.

Technical Specifications

Filter Standard EN 1822 and ISO 29463 Maximum Operating Temperature 80°C
Filter Classes E10, E11, E12, H13 and H14 Depth 130 mm
Filter Media Glass fiber Surface Protection Optional
Frame Type Polystyrene plastic Sealing Compound Two-component polyurethane
Recommended Final Pressure Drop 2× initial pressure drop, maximum 600 Pa Separator Hot-melt adhesive

For additional information about international air-filter standards, visit the official ISO website.

Product Coding System

The product code identifies the filter type, efficiency class, frame material, flange size, external dimensions, surface protection and gasket option.

Example product code: AR-H14-P-25-592-592-130-FC-E
Code Section Options Description
Filter Type AR High Efficiency Rigid Filter with plastic frame
Filter Class E10 / E11 / E12 / H13 / H14 Efficiency class according to EN 1822 and ISO 29463
Frame P Plastic polystyrene frame
Flange 25 25 mm flange
Dimensions Width × Height × Depth Example: 592 × 592 × 130 mm
Surface Protection FW / FC / FD / FB FW: No surface protection
FC: Clean-air side
FD: Dirty-air side
FB: Both sides
Gasket W / P / PP / E / EE / C / CC W: No gasket
P: Poured gasket
PP: Double-sided poured gasket
E: EPDM gasket
EE: Double-sided EPDM gasket
C: Gray EPDM gasket
CC: Double-sided gray EPDM gasket

Filter Models and Performance Data

Filter Model EN 1822 ISO 29463 Dimensions W×H×D
(mm)
Filtration Area
(m²)
Nominal Airflow
(m³/h)
Initial Pressure Drop
(Pa)
AR-E10-P-25-287-287-130-FW-W E10 – 287 × 287 × 130 3.2 625 190
AR-E10-P-25-287-592-130-FW-W E10 – 287 × 592 × 130 6.5 1,250 190
AR-E10-P-25-592-592-130-FW-W E10 – 592 × 592 × 130 13 2,500 190
AR-E11-P-25-287-287-130-FW-W E11 ISO 15 E 287 × 287 × 130 3.2 500 210
AR-E11-P-25-287-592-130-FW-W E11 ISO 15 E 287 × 592 × 130 6.5 1,000 210
AR-E11-P-25-592-592-130-FW-W E11 ISO 15 E 592 × 592 × 130 13 2,000 210
AR-E12-P-25-287-287-130-FW-W E12 ISO 25 E 287 × 287 × 130 3.2 375 250
AR-E12-P-25-287-592-130-FW-W E12 ISO 25 E 287 × 592 × 130 6.5 750 250
AR-E12-P-25-592-592-130-FW-W E12 ISO 25 E 592 × 592 × 130 13 1,500 250
AR-H13-P-25-287-287-130-FC-E H13 ISO 35 H 287 × 287 × 130 3.2 375 270
AR-H13-P-25-287-592-130-FC-E H13 ISO 35 H 287 × 592 × 130 6.5 750 270
AR-H13-P-25-592-592-130-FC-E H13 ISO 35 H 592 × 592 × 130 13 1,500 270
AR-H14-P-25-287-287-130-FC-E H14 ISO 45 H 287 × 287 × 130 3.2 300 270
AR-H14-P-25-287-592-130-FC-E H14 ISO 45 H 287 × 592 × 130 6.5 600 270
AR-H14-P-25-592-592-130-FC-E H14 ISO 45 H 592 × 592 × 130 13 1,200 270
Note: Initial differential-pressure tolerance is ±10%. The listed standard models use a 130 mm depth and a 25 mm flange.

Structural Components

Glass-Fiber Filter Media
Fine-fiber media supports high-efficiency filtration classes from E10 to H14.
Polystyrene Frame
The rigid plastic frame combines low weight with corrosion resistance.
Polyurethane Sealing
Two-component polyurethane seals the connection between the filter pack and plastic frame.
Hot-Melt Separators
They maintain mini-pleat spacing and help preserve airflow channels.
Gasket Options
Poured, EPDM, gray EPDM and double-sided gasket options suit different filter housings.

Application Areas

  • Final filtration in air handling units
  • HVAC equipment
  • Cleanroom ventilation systems
  • Pharmaceutical production and laboratories
  • Hospitals and healthcare facilities
  • Industrial systems requiring compact high-efficiency filtration

Product Advantages

  • Large filtration area
  • Lightweight polystyrene frame
  • Corrosion-resistant plastic body
  • Compact and rigid filter pack
  • E10, E11, E12, H13 and H14 options
  • Multiple gasket and surface-protection options

Filter Selection Criteria

Filter ClassChoose E10–H14 according to the required particle efficiency and clean-area requirements.
Nominal AirflowCompare actual airflow per filter with the nominal airflow in the model table.
Filter DimensionsWidth, height and the 130 mm depth must match the existing filter housing.
FlangeCheck compatibility of the 25 mm flange with the housing and clamping mechanism.
Gasket TypeSelect poured or EPDM gaskets according to the contact surface and airflow direction.
System PressureCheck initial pressure drop together with available fan pressure and energy consumption.

Maintenance and Replacement

First, monitor differential pressure across the filter regularly. During periodic maintenance, inspect the plastic frame, filter media, surface protection and gasket. Also verify correct seating inside the filter housing.

The recommended final pressure drop is approximately twice the clean-filter value. However, it should not exceed 600 Pa. In addition, consider air quality, fan energy consumption and process conditions when planning replacement.

Do not wash the glass-fiber media or clean it with compressed air. Likewise, avoid mechanical impact on the filter pack. Do not expose the plastic frame to excessive temperature or incompatible chemicals.

Technical Application Note

The filtration area, nominal airflow and initial differential pressure shown in the table refer to standard product conditions. Actual performance can vary with installation, housing leakage, airflow, system pressure, filter face velocity, test conditions, instrument calibration, dust load, humidity, temperature, filter loading and airflow distribution. Therefore, define individual testing and certification requirements for H13 and H14 filters before ordering.

Select the Right Plastic Rigid Filter for Your Project

Send us the required filter class, nominal airflow, filter-cell dimensions, gasket type, surface protection and operating conditions. We can then support technical selection and quotation preparation.

You can also review our industrial HVAC and filtration services.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information