Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

HVAC Model V-Compact Filter

HVAC Model V-Compact Filter

ISO 16890 FINE FILTRATION

HVAC Model V-Compact Filter

HVAC Model V-Compact Filter is a high-capacity compact air filter. Furthermore, it is used in air handling units and industrial ventilation systems. It captures fine particles, works as second or final stage filtration and protects HEPA filters through pre-filtration.

Glass fibre filter packs are placed in a V shape. Therefore, a large filtration area fits into compact outer dimensions. In addition, the structure combines a polystyrene frame, hot-melt separators and a two-component polyurethane sealing compound. As a result, the range covers HVAC applications with operating air flow rates between 1,700 and 3,400 m³/h.

ISO ePM1–ePM10
V-Compact Design
Polystyrene Frame
HVAC Model V-Compact Filter ISO 16890 air filter

Filter Standard
ISO 16890
Nominal Air Flow
2,125–4,250 m³/h
Filtration Area
7–14 m²
Maximum Temperature
80°C

What Is the HVAC Model V-Compact Filter?

The HVAC Model V-Compact Filter is a fine particle filter with a large surface area. Several mini-pleat filter packs are placed inside a polystyrene frame in V geometry. Consequently, high air flow rates can be handled in standard panel dimensions.

Hot-melt separators protect the pleat spacing of the glass fibre media. Moreover, the joints between the filter packs and the outer frame are sealed with a two-component polyurethane compound. This detail supports circumferential tightness.

The filtration area varies between 7 and 14 m². Therefore, high dust holding capacity and a controlled initial pressure drop can be achieved at suitable air flow rates. In addition, the product is offered in ISO ePM10 75%, ISO ePM1 55%, ISO ePM1 75% and ISO ePM1 80% classes. For the complete range, you can also visit our air filter products page.

Filter Selection and Application Process

01
Air Flow Analysis
First, the nominal and the real operating air flow rates are defined separately.
02
Filter Class
Then, ISO ePM1 or ISO ePM10 efficiency is chosen according to the target particle size.
03
Dimension Check
Next, the filter cell width, height and 292 mm depth compatibility are checked.
04
Sealing Selection
Afterwards, face guard and gasket options are defined according to the filter housing.
05
Pressure Monitoring
Finally, the operating pressure drop is followed with differential pressure measurement.

Technical Specifications

Filter standard ISO 16890 Filter classes ISO ePM1, ISO ePM2.5 and ISO ePM10
Filter media Glass fibre Frame type Polystyrene (PS)
Standard depth 292 mm Filtration area 7–14 m²
Maximum operating temperature 80°C Face guard Optional
Gasket Optional Sealing compound Two-component polyurethane
Separator Hot melt Operating air flow 1,700–3,400 m³/h
Recommended final pressure drop According to the EN 13053 approach, initial ΔP + 100 Pa or initial ΔP × 3, whichever is lower
Standard note: The EN 779 standard has been withdrawn. Therefore, the M6, F7, F8 and F9 designations are shown only for historical classification and for comparison with existing legacy projects. Current selection and performance evaluation must be based on the ISO 16890 classification.
Eurovent or similar third-party certificates and energy class data must be verified separately during the project stage. In addition, this verification should cover the current product model, size, air flow rate, filter class and valid certificate scope.

Product Coding System

Product Type Filter Class Dimensions Face Guard Gasket
AR
HVAC Model V-Compact Filter
M6
F7
F8
F9
Width × Height × Depth
Example: 592 × 592 × 292 mm
FW: None
FC2: On 2 sides
FC8: On 8 sides
W: None
P: Poured gasket
PP: Double sided poured gasket
E: EPDM
EE: Double sided EPDM gasket
Sample Product Code
AR-F8-592-592-292-FC2-E
HVAC Model V-Compact filter – historical F8 class – 592 × 592 × 292 mm – face guard on 2 sides – EPDM gasket

HVAC Model V-Compact Filter Models

Filter Model EN 779
(withdrawn)
ISO 16890 Dimensions
W × H × D
(mm)
Filtration Area
(m²)
Nominal Air Flow
(m³/h)
Initial Pressure at Nominal Flow
(Pa)
Operating Air Flow
(m³/h)
Initial Pressure at Operating Flow
(Pa)
Energy Class
AR-M6-287-592-292-FW-W M6 ePM10 75% 287 × 592 × 292 7 2,125 108 1,700 80 E
AR-M6-490-592-292-FW-W M6 ePM10 75% 490 × 592 × 292 11.5 3,500 108 2,700 80 E
AR-M6-592-592-292-FW-W M6 ePM10 75% 592 × 592 × 292 14 4,250 108 3,400 80 E
AR-F7-287-592-292-FW-W F7 ePM1 55% 287 × 592 × 292 7 2,125 130 1,700 90 D
AR-F7-490-592-292-FW-W F7 ePM1 55% 490 × 592 × 292 11.5 3,500 130 2,700 90 D
AR-F7-592-592-292-FW-W F7 ePM1 55% 592 × 592 × 292 14 4,250 130 3,400 90 D
AR-F8-287-592-292-FW-W F8 ePM1 75% 287 × 592 × 292 7 2,125 150 1,700 100 C
AR-F8-490-592-292-FW-W F8 ePM1 75% 490 × 592 × 292 11.5 3,500 150 2,700 100 C
AR-F8-592-592-292-FW-W F8 ePM1 75% 592 × 592 × 292 14 4,250 150 3,400 100 C
AR-F9-287-592-292-FW-W F9 ePM1 80% 287 × 592 × 292 7 2,125 185 1,700 120 D
AR-F9-490-592-292-FW-W F9 ePM1 80% 490 × 592 × 292 11.5 3,500 185 2,700 120 D
AR-F9-592-592-292-FW-W F9 ePM1 80% 592 × 592 × 292 14 4,250 185 3,400 120 D
Production and tolerance note: Production in special dimensions depends on technical feasibility confirmation. Moreover, the pressure difference tolerance should be evaluated by taking the greater value of “±10% + 5 Pa” or “10 Pa + 5 Pa”.

Structural Components

Glass Fibre Filter Media
This filtration material is used in a mini-pleat structure. Therefore, fine particles can be captured efficiently.
V-Shaped Filter Packs
They increase the filter surface. As a result, high air flow can be handled in compact outer dimensions.
Polystyrene Frame
It gives the product a light and mechanically rigid outer construction.
Hot-Melt Separator
In addition, it helps to protect the mini-pleat spacing and the air passage channels.
Polyurethane Sealing
It provides circumferential tightness where the filter packs meet the frame.
Gasket and Face Guard
Different options can be applied according to the filter housing and mounting details.

Application Areas

Capture of fine particles
Second stage filtration in air handling units
Final stage filtration in air handling units
Pre-filtration for HEPA filters
Industrial ventilation systems
HVAC applications with high air flow

Product Advantages

Large filtration area: V-shaped packs provide up to 14 m² of filter surface.
High air flow: Nominal air flow options reach up to 4,250 m³/h.
Compact design: Moreover, it collects a large filter surface in standard HVAC filter dimensions.
Light frame: Therefore, the polystyrene structure can simplify handling and filter replacement.
Low operating pressure: Reference initial pressures stay between 80 and 120 Pa at operating air flow rates.
Different sealing options: In addition, poured gasket, EPDM and face guard alternatives are available.

Filter Selection Criteria

  • Nominal and real operating air flow rate
  • Target ISO 16890 filter class
  • Width and height of the filter cell
  • Available space for the 292 mm filter depth
  • Permitted initial and final pressure drop
  • Filtration area and filter face velocity
  • Face guard side and mounting direction
  • Gasket and clamping mechanism
  • Dust concentration and particle characteristics
  • Ambient temperature, relative humidity and chemical conditions

Inspection and Maintenance

The filter pressure drop should be monitored regularly. For this purpose, a differential pressure gauge or a pressure transmitter can be used. Moreover, the replacement decision must not be based on operating hours alone. Real pressure drop, air flow rate, dust load and the physical condition of the filter should also be considered.

Glass fibre media must not be cleaned with water or compressed air unless it is defined as washable. Otherwise, unsuitable cleaning can damage the mini-pleat structure, the hot-melt separators, the sealing compound and the polystyrene frame.

Frequently Asked Questions

What is the difference between a V-Compact filter and a rigid filter?
In a V-Compact filter, several filter packs are placed in V geometry. Therefore, a larger filtration area and a higher air flow can be reached with similar face dimensions.
Can the HVAC Model V-Compact Filter replace a HEPA filter?
No. This product is a fine particle filter under ISO 16890. However, it can be used upstream of a HEPA filter. It does not replace the HEPA filter class.
Why are the nominal and the operating air flow rates different?
The nominal air flow expresses the reference upper working value of the product. In contrast, the operating air flow is the lower value used for energy and pressure drop evaluations.
Does the energy class stay the same in every project?
No. It depends on the product model, filter class, test flow rate, pressure drop and the valid certification programme. Therefore, current certificate data must be verified at the project and order stage.
Can V-Compact filters be produced in special dimensions?
Yes, in principle. However, the filter pack geometry, air flow, pressure drop, frame strength and production limits must be checked first. Special sizes are then evaluated on a project basis.

Technical Application Note
The air flow, filtration area, initial pressure drop and energy class values given in the tables are reference product data. However, real performance can change depending on process conditions. Mounting method, test area, real air flow, filter face velocity, system pressure, environmental leakage, filter housing tightness, gasket compression, air distribution, calibration of measuring devices, dust load, particle size, relative humidity, temperature and service life all have an effect. In addition, the temperature and chemical resistance of the polystyrene frame must be evaluated together with the application conditions.

Selecting the Right V-Compact Filter for Your Project

You can contact Airtes for HVAC Model V-Compact filter selection. Please share the air flow rate, ISO 16890 class, filter size, pressure drop, face guard and gasket requirements of your project. Our technical team will then support you with a suitable option.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information