HVAC Model V-Compact Filter
HVAC Model V-Compact Filter is a high-capacity compact air filter. Furthermore, it is used in air handling units and industrial ventilation systems. It captures fine particles, works as second or final stage filtration and protects HEPA filters through pre-filtration.
Glass fibre filter packs are placed in a V shape. Therefore, a large filtration area fits into compact outer dimensions. In addition, the structure combines a polystyrene frame, hot-melt separators and a two-component polyurethane sealing compound. As a result, the range covers HVAC applications with operating air flow rates between 1,700 and 3,400 m³/h.
V-Compact Design
Polystyrene Frame

What Is the HVAC Model V-Compact Filter?
The HVAC Model V-Compact Filter is a fine particle filter with a large surface area. Several mini-pleat filter packs are placed inside a polystyrene frame in V geometry. Consequently, high air flow rates can be handled in standard panel dimensions.
Hot-melt separators protect the pleat spacing of the glass fibre media. Moreover, the joints between the filter packs and the outer frame are sealed with a two-component polyurethane compound. This detail supports circumferential tightness.
The filtration area varies between 7 and 14 m². Therefore, high dust holding capacity and a controlled initial pressure drop can be achieved at suitable air flow rates. In addition, the product is offered in ISO ePM10 75%, ISO ePM1 55%, ISO ePM1 75% and ISO ePM1 80% classes. For the complete range, you can also visit our air filter products page.
Filter Selection and Application Process
Technical Specifications
| Filter standard | ISO 16890 | Filter classes | ISO ePM1, ISO ePM2.5 and ISO ePM10 |
| Filter media | Glass fibre | Frame type | Polystyrene (PS) |
| Standard depth | 292 mm | Filtration area | 7–14 m² |
| Maximum operating temperature | 80°C | Face guard | Optional |
| Gasket | Optional | Sealing compound | Two-component polyurethane |
| Separator | Hot melt | Operating air flow | 1,700–3,400 m³/h |
| Recommended final pressure drop | According to the EN 13053 approach, initial ΔP + 100 Pa or initial ΔP × 3, whichever is lower | ||
Product Coding System
| Product Type | Filter Class | Dimensions | Face Guard | Gasket |
|---|---|---|---|---|
| AR HVAC Model V-Compact Filter |
M6 F7 F8 F9 |
Width × Height × Depth Example: 592 × 592 × 292 mm |
FW: None FC2: On 2 sides FC8: On 8 sides |
W: None P: Poured gasket PP: Double sided poured gasket E: EPDM EE: Double sided EPDM gasket |
HVAC Model V-Compact Filter Models
| Filter Model | EN 779 (withdrawn) |
ISO 16890 | Dimensions W × H × D (mm) |
Filtration Area (m²) |
Nominal Air Flow (m³/h) |
Initial Pressure at Nominal Flow (Pa) |
Operating Air Flow (m³/h) |
Initial Pressure at Operating Flow (Pa) |
Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| AR-M6-287-592-292-FW-W | M6 | ePM10 75% | 287 × 592 × 292 | 7 | 2,125 | 108 | 1,700 | 80 | E |
| AR-M6-490-592-292-FW-W | M6 | ePM10 75% | 490 × 592 × 292 | 11.5 | 3,500 | 108 | 2,700 | 80 | E |
| AR-M6-592-592-292-FW-W | M6 | ePM10 75% | 592 × 592 × 292 | 14 | 4,250 | 108 | 3,400 | 80 | E |
| AR-F7-287-592-292-FW-W | F7 | ePM1 55% | 287 × 592 × 292 | 7 | 2,125 | 130 | 1,700 | 90 | D |
| AR-F7-490-592-292-FW-W | F7 | ePM1 55% | 490 × 592 × 292 | 11.5 | 3,500 | 130 | 2,700 | 90 | D |
| AR-F7-592-592-292-FW-W | F7 | ePM1 55% | 592 × 592 × 292 | 14 | 4,250 | 130 | 3,400 | 90 | D |
| AR-F8-287-592-292-FW-W | F8 | ePM1 75% | 287 × 592 × 292 | 7 | 2,125 | 150 | 1,700 | 100 | C |
| AR-F8-490-592-292-FW-W | F8 | ePM1 75% | 490 × 592 × 292 | 11.5 | 3,500 | 150 | 2,700 | 100 | C |
| AR-F8-592-592-292-FW-W | F8 | ePM1 75% | 592 × 592 × 292 | 14 | 4,250 | 150 | 3,400 | 100 | C |
| AR-F9-287-592-292-FW-W | F9 | ePM1 80% | 287 × 592 × 292 | 7 | 2,125 | 185 | 1,700 | 120 | D |
| AR-F9-490-592-292-FW-W | F9 | ePM1 80% | 490 × 592 × 292 | 11.5 | 3,500 | 185 | 2,700 | 120 | D |
| AR-F9-592-592-292-FW-W | F9 | ePM1 80% | 592 × 592 × 292 | 14 | 4,250 | 185 | 3,400 | 120 | D |
Structural Components
Application Areas
Product Advantages
Filter Selection Criteria
- Nominal and real operating air flow rate
- Target ISO 16890 filter class
- Width and height of the filter cell
- Available space for the 292 mm filter depth
- Permitted initial and final pressure drop
- Filtration area and filter face velocity
- Face guard side and mounting direction
- Gasket and clamping mechanism
- Dust concentration and particle characteristics
- Ambient temperature, relative humidity and chemical conditions
Inspection and Maintenance
The filter pressure drop should be monitored regularly. For this purpose, a differential pressure gauge or a pressure transmitter can be used. Moreover, the replacement decision must not be based on operating hours alone. Real pressure drop, air flow rate, dust load and the physical condition of the filter should also be considered.
Glass fibre media must not be cleaned with water or compressed air unless it is defined as washable. Otherwise, unsuitable cleaning can damage the mini-pleat structure, the hot-melt separators, the sealing compound and the polystyrene frame.
Frequently Asked Questions
Selecting the Right V-Compact Filter for Your Project
You can contact Airtes for HVAC Model V-Compact filter selection. Please share the air flow rate, ISO 16890 class, filter size, pressure drop, face guard and gasket requirements of your project. Our technical team will then support you with a suitable option.