      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

Pass Box Control Systems

Pass Box Control Systems

CONTROLLED MATERIAL TRANSFER FOR CLEANROOMS AND LABORATORIES

Pass Box Control Systems

Safe Pass-Through Box Solutions for Cleanrooms, Laboratories and Hygienic Production Areas

Pass box control systems are pass-through box solutions used for the controlled transfer of materials, samples, equipment or consumables in cleanrooms and laboratories.

Pass box systems can be manufactured with an electrostatic powder-coated DKP steel body or a stainless-steel housing and designed as active or passive models. Active models can include an H13 / H14 HEPA filter, pressurisation fan, fan filter unit, magnetic lock, magnetic contact, electronic control display and alarm system as standard equipment.

✆CONTACT US

Pass box control systems for cleanroom material transfer

Active / Passive Model

Can be manufactured as an active fan-filtered or passive transfer box according to the application area.

H13 / H14 HEPA Filter

In the active model, ISO 5 cabinet class can be targeted with a high-efficiency HEPA filter and pressurisation fan.

Magnetic Lock System

Provides safe transfer with a magnetic lock and magnetic contact system that prevents opposite doors from opening simultaneously.

What Is a Pass Box?

A pass box is a controlled transfer box used to reduce airflow, particle transfer and cross-contamination risks while transferring materials between a cleanroom and the outside environment or two areas with different cleanliness classes.

Material transfers must be controlled in cleanrooms, laboratories, pharmaceutical manufacturing, biotechnology, food, electronics production and hospital hygiene areas. Pass box systems make these transfers safer, more controlled and more hygienic.

Pass Box Control Systems Operating Principle

1

Material PlacementThe product to be transferred is placed inside the cabin through the outer pass box door.

2

Door Locking ControlThe magnetic lock and contact system prevent the two doors from opening at the same time.

3

HEPA FiltrationIn the active model, the fan filter unit circulates or supplies air passing through an H13 / H14 HEPA filter inside the cabin.

4

Safe ReceivingAfter the control process is complete, the cleanroom-side door opens and the material is received.

Key Technical Features

Body Options: Electrostatic powder-coated DKP steel or stainless-steel housing.
Model Options: Active fan-filtered or passive pass-through box model.
Filtration: H13 / H14 HEPA filter can be used in the active model.
Fan Unit: Pressurisation fan and fan filter unit can provide internal cabin air control.
Control Equipment: Magnetic lock, magnetic contact, electronic control display and alarm system.
Air Supply Flexibility: Can be designed with recirculation, cleanroom air supply or ventilation duct connection.

Pass Box Technical Information Table

Technical Feature Standard Value Description
Product type Pass Box / Pass-Through Box Used for controlled material transfer in cleanrooms and laboratories.
Model Active or passive The active model includes a HEPA filter and pressurisation fan.
Airflow rate 150 m³/h Standard value for active-model air circulation / supply.
Internal cabin dimensions 400 x 400 x 600 mm Standard internal usable volume.
HEPA filter dimensions 305 x 305 x 69 mm Filter dimensions used in the active model.
HEPA filter class H13 / H14 Provides high-efficiency particulate filtration in cleanroom applications.
Cabinet class ISO 5 Target cabinet cleanliness for the actively filtered model.
Cycle count >1500 Specified for internal cabin air-change / circulation performance.
Power 100 W / 0.75 A Standard active-model power consumption.
Power supply 230V / 50 Hz Standard mains supply.

Active and Passive Pass Box Comparison

Feature Passive Pass Box Active Pass Box
Purpose of use Material transfer between areas with the same or similar cleanliness level Areas requiring more controlled transfer and internal HEPA filtration
Fan filter unit Not included Included as standard
HEPA filter Generally not applied H13 / H14 HEPA filter can be applied
Air movement Natural transfer volume Can be designed with recirculation or outdoor-air / duct supply
Control system Magnetic lock and contact system Magnetic lock, contact, electronic control, alarm and fan control

Standard Equipment

Magnetic lock system
Magnetic contact system
Electronic control display
Alarm system
Fan filter unit
H13 / H14 HEPA filter

Air Supply Options

Recirculated OperationThe fan can circulate the existing air in the unit through the HEPA filter, creating a clean-air cycle inside the cabin.
Cleanroom Air SupplyCan be designed for controlled air intake from the cleanroom according to the application area.
Ventilation Duct ConnectionA project-specific connection detail can be created to allow air intake from existing ventilation ducts.

Areas of Use

Cleanrooms
Laboratories
Pharmaceutical production facilities
Biotechnology areas
Hygienic food-production areas
Electronics production areas

Advantages of Pass Box Control Systems

Provides controlled material transfer between the cleanroom and the outside environment.
Reduces cross-contamination risk by preventing opposite doors from opening at the same time.
Improves internal cabin air quality through HEPA filtration in the active model.
Can be adapted to different hygiene needs with coated DKP or stainless-steel housing options.
Provides safe use with an electronic control display and alarm system.
Can be designed with recirculation, cleanroom air supply or duct connection.

Application Note

When selecting a pass box, the cleanroom class, dimensions of the item to be transferred, active / passive model need, HEPA filter class, airflow rate, cabin dimensions, body material, door direction, locking system, alarm function, air supply method and validation requirements should be evaluated together.

Get Technical Support for Pass Box Control System Selection

Pass box systems should be designed according to cleanroom class, transfer volume, active / passive operating type, HEPA filtration need and body material.

You can request a project-based technical assessment for pass box control systems for cleanrooms, laboratories, pharmaceutical, food, biotechnology and electronics production areas.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information