Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

Polyurethane FAN-COIL Filter

Polyurethane FAN-COIL Filter

WASHABLE COARSE AIR FILTER

Polyurethane FAN-COIL Filter

Polyurethane FAN-COIL Filter is a panel filter with washable polyurethane media. It is designed to capture coarse dust, fibers, lint and similar large particles from the return air of fan-coil units.

Washable Media, Galvanized Frame and Slim Panel Design

The polyurethane filter media is installed inside a galvanized frame and supported by expanded metal mesh on both sides. Therefore, the structure helps the filter maintain its shape under airflow.

According to ISO 16890, the product is evaluated in the ISO Coarse class. In addition, it can be manufactured in standard or custom dimensions for different fan-coil filter housings.

✆CONTACT US

Polyurethane FAN-COIL Filter for washable HVAC return-air prefiltration

Washable Media

The polyurethane filter media can be cleaned using suitable maintenance procedures.

ISO Coarse 25%

It helps capture coarse particles from fan-coil return air.

Galvanized Frame

Provides a durable panel structure with double-sided expanded metal support.

Custom Manufacturing

Can be produced in dimensions suitable for different fan-coil filter housings.

What Is a Polyurethane FAN-COIL Filter?

The Polyurethane FAN-COIL Filter is a prefilter used to capture coarse particles carried with room air before they reach the coil and fan section of the fan-coil unit.

Open-cell polyurethane media allows airflow while helping retain coarse dust on the filter surface and within its porous structure. Moreover, its washable construction allows the filter to be reused after suitable maintenance and complete drying.

The galvanized frame and double-sided expanded metal mesh help keep the filter media fixed inside the panel. As a result, excessive deformation under airflow is reduced.

Operating Principle

1

Air Reaches the Filter
Return air passes through the filter surface due to the suction effect of the fan.

2

Particles Are Captured
Coarse dust, fibers and lint are retained within the porous polyurethane media.

3

Equipment Is Protected
Filtered air reaches the coil and helps limit internal contamination of the fan-coil unit.

4

Filter Is Cleaned
Finally, the dirty filter is washed using a suitable method, completely dried and reinstalled.

Technical Specifications

Technical Parameter Value Technical Parameter Value
Filter Standard ISO 16890 Recommended Final Pressure Drop Initial ΔP + 50 Pa or initial ΔP × 3; whichever is lower
Filter Class ISO Coarse Maximum Operating Temperature 80°C
Filter Material Polyurethane Standard Depth 6–8–10 mm
Frame Galvanized Expanded Metal Mesh Double-sided

Product Coding Table

Filter Type Filter Class Frame Dimensions
AR: Polyurethane FAN-COIL Filter G2 G: Galvanized 400–1,500 × 8 mm
Example product code:
AR-G2-G-175-1000-8

Polyurethane FAN-COIL Filter Model and Performance Table

The following models use G2 / ISO Coarse 25% polyurethane media. Their initial pressure-drop values are given at an air velocity of 2 m/s.

Filter Model EN 779
Withdrawn
ISO 16890 Material Width
mm
Height
mm
Depth
mm
Air Velocity
m/s
Initial Pressure Drop
Pa
AR-G2-G-175-(400 to 1500)-8 G2 Coarse 25% Polyurethane 175 400–1,500 8 2 45
AR-G2-G-185-(400 to 1500)-8 G2 Coarse 25% Polyurethane 185 400–1,500 8 2 45
AR-G2-G-205-(400 to 1500)-8 G2 Coarse 25% Polyurethane 205 400–1,500 8 2 45
AR-G2-G-210-(400 to 1500)-8 G2 Coarse 25% Polyurethane 210 400–1,500 8 2 45
AR-G2-G-245-(400 to 1500)-8 G2 Coarse 25% Polyurethane 245 400–1,500 8 2 45
Manufacturing and tolerance notes:
Custom dimensions can be manufactured.
Differential-pressure tolerance may be evaluated according to whichever is greater: ±10% + 5 Pa or 10 Pa + 5 Pa.

Application Areas

Cassette fan-coil units
Floor-mounted fan-coil units
Ceiling-mounted fan-coil units
Ducted fan-coil units
Office and administrative buildings
Hotels and accommodation facilities
Shopping centers
Residential and commercial buildings

Product Advantages

Washable polyurethane filter media
Suitable structure for capturing coarse dust and fibers
Galvanized metal frame
Double-sided expanded metal support
Slim and compact panel design
Custom-size manufacturing
Easy removal, installation and maintenance
Helps reduce contamination of fan-coil coils

Washing and Maintenance Instructions

Remove the filter only after the fan-coil unit has been switched off and isolated from its energy supply.
Next, loose surface dust can be removed using low-pressure air or a suitable vacuum method.
Wash the filter media using water at a suitable temperature and a cleaning method compatible with the material.
However, do not use high-pressure water, hard brushes or chemicals that may damage the filter media.
The washed filter must be completely dried without direct sunlight or high-temperature exposure.
Replace the filter if the media is torn, hardened, has lost its pore structure or is permanently deformed.

Technical Selection Note

Polyurethane FAN-COIL Filters are intended for coarse-particle filtration. They are not sufficient by themselves for applications requiring fine-particle filtration, high hygiene, gas filtration, odor control or chemical-vapor removal.

After washing, the filter should not be installed in the fan-coil unit until it is completely dry. A damp filter may contribute to odor, microbial growth and unwanted moisture accumulation inside the unit.

Actual pressure drop and maintenance intervals can vary according to filter dimensions, face velocity, room dust load, operating time, washing method and process conditions.

For further reference on general ventilation air-filter classification, see the official ISO 16890-1 standard page.

Get Technical Support for Polyurethane FAN-COIL Filter

Product selection should consider the clear dimensions of the fan-coil filter housing, airflow, face velocity, initial pressure drop and maintenance conditions.

Contact Airtes for technical support in selecting and supplying standard or custom-size Polyurethane FAN-COIL Filters.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik