Rigid Filter (Aluminum Frame)
Rigid Filter (Aluminum Frame) is a compact air filter used to capture fine particles in HVAC systems, provide second- or final-stage filtration, and protect HEPA filters against excessive particulate loading.
Glass-fiber filter media, hot-melt separators, two-component polyurethane sealing compound and an aluminum frame provide a rigid filter construction. Standard-capacity 100 mm models and high-capacity 130 mm models can be selected according to filtration area and pressure-drop requirements.
100 and 130 mm
Aluminum Frame

What Is a Rigid Filter?
A rigid filter is a fine-filtration element manufactured by securing densely pleated glass-fiber media inside a durable frame. The aluminum frame combines low weight with mechanical rigidity. It also helps the filter retain its form during installation in the filter housing.
Hot-melt separators maintain the spacing between the filter-media pleats. Therefore, airflow passages remain open and the available filter surface can be used effectively. A two-component polyurethane compound at the media-to-frame joints supports perimeter sealing.
The 100 mm models provide standard capacity, while the 130 mm models offer a larger filtration area and high-capacity construction. A larger filter area can help reduce the initial pressure drop at the same nominal airflow.
Filter Selection and Application Process
Technical Specifications
| Filter standard | ISO 16890 | Filter classes | ISO ePM1, ISO ePM2.5 and ISO ePM10 |
| Filter media | Glass fiber | Frame | Aluminum |
| Standard depth | 100 and 130 mm | Capacity | Standard or high capacity |
| Maximum operating temperature | 80°C | Surface protection | Optional |
| Sealing compound | Two-component polyurethane | Separator | Hot-melt adhesive |
| Flange options | 20 or 25 mm | Gasket options | No gasket, EPDM or double-sided EPDM |
| Recommended final pressure drop | According to the EN 13053 approach, whichever is lower: initial ΔP + 100 Pa or initial ΔP × 3 | ||
Product Coding System
| Product Type | Filter Class | Frame | Capacity | Flange | Dimensions | Surface Protection | Gasket |
|---|---|---|---|---|---|---|---|
| AR Rigid Filter |
M6 F7 F8 F9 |
A: Aluminum | M: Standard capacity H: High capacity |
20: 20 mm 25: 25 mm |
Width × Height × Depth Example: 592 × 592 × 130 mm |
FW: None FC: Clean-air side FD: Dirty-air side FB: Both sides |
W: None E: EPDM EE: Double-sided EPDM |
Rigid Filter (Aluminum Frame) / 100 mm
| Filter Model | EN 779 (withdrawn) |
ISO 16890 | Dimensions W × H × D (mm) |
Filtration Area (m²) |
Nominal Airflow (m³/h) |
Initial Pressure Drop (Pa) |
|---|---|---|---|---|---|---|
| AR-M6-A-M-25-287-287-100-FW-W | M6 | ePM10 70% | 287 × 287 × 100 | 2.5 | 750 | 100 |
| AR-M6-A-M-25-287-592-100-FW-W | M6 | ePM10 70% | 287 × 592 × 100 | 5 | 1,500 | 100 |
| AR-M6-A-M-25-490-592-100-FW-W | M6 | ePM10 70% | 490 × 592 × 100 | 8.3 | 2,500 | 100 |
| AR-M6-A-M-25-592-592-100-FW-W | M6 | ePM10 70% | 592 × 592 × 100 | 10 | 3,000 | 100 |
| AR-F7-A-M-25-287-287-100-FW-W | F7 | ePM1 55% | 287 × 287 × 100 | 2.5 | 750 | 125 |
| AR-F7-A-M-25-287-592-100-FW-W | F7 | ePM1 55% | 287 × 592 × 100 | 5 | 1,500 | 125 |
| AR-F7-A-M-25-490-592-100-FW-W | F7 | ePM1 55% | 490 × 592 × 100 | 8.3 | 2,500 | 125 |
| AR-F7-A-M-25-592-592-100-FW-W | F7 | ePM1 55% | 592 × 592 × 100 | 10 | 3,000 | 125 |
| AR-F8-A-M-25-287-287-100-FW-W | F8 | ePM1 65% | 287 × 287 × 100 | 2.5 | 750 | 150 |
| AR-F8-A-M-25-287-592-100-FW-W | F8 | ePM1 65% | 287 × 592 × 100 | 5 | 1,500 | 150 |
| AR-F8-A-M-25-490-592-100-FW-W | F8 | ePM1 65% | 490 × 592 × 100 | 8.3 | 2,500 | 150 |
| AR-F8-A-M-25-592-592-100-FW-W | F8 | ePM1 65% | 592 × 592 × 100 | 10 | 3,000 | 150 |
| AR-F9-A-M-25-287-287-100-FW-W | F9 | ePM1 85% | 287 × 287 × 100 | 2.5 | 750 | 170 |
| AR-F9-A-M-25-287-592-100-FW-W | F9 | ePM1 85% | 287 × 592 × 100 | 5 | 1,500 | 170 |
| AR-F9-A-M-25-490-592-100-FW-W | F9 | ePM1 85% | 490 × 592 × 100 | 8.3 | 2,500 | 170 |
| AR-F9-A-M-25-592-592-100-FW-W | F9 | ePM1 85% | 592 × 592 × 100 | 10 | 3,000 | 170 |
Rigid Filter (Aluminum Frame) / 130 mm
| Filter Model | EN 779 (withdrawn) |
ISO 16890 | Dimensions W × H × D (mm) |
Filtration Area (m²) |
Nominal Airflow (m³/h) |
Initial Pressure Drop (Pa) |
|---|---|---|---|---|---|---|
| AR-M6-A-H-25-287-287-130-FW-W | M6 | ePM10 75% | 287 × 287 × 130 | 3.2 | 750 | 90 |
| AR-M6-A-H-25-287-592-130-FW-W | M6 | ePM10 75% | 287 × 592 × 130 | 6.5 | 1,500 | 90 |
| AR-M6-A-H-25-490-592-130-FW-W | M6 | ePM10 75% | 490 × 592 × 130 | 10.7 | 2,500 | 90 |
| AR-M6-A-H-25-592-592-130-FW-W | M6 | ePM10 75% | 592 × 592 × 130 | 13 | 3,000 | 90 |
| AR-F7-A-H-25-287-287-130-FW-W | F7 | ePM1 55% | 287 × 287 × 130 | 3.2 | 750 | 110 |
| AR-F7-A-H-25-287-592-130-FW-W | F7 | ePM1 55% | 287 × 592 × 130 | 6.5 | 1,500 | 110 |
| AR-F7-A-H-25-490-592-130-FW-W | F7 | ePM1 55% | 490 × 592 × 130 | 10.7 | 2,500 | 110 |
| AR-F7-A-H-25-592-592-130-FW-W | F7 | ePM1 55% | 592 × 592 × 130 | 13 | 3,000 | 110 |
| AR-F8-A-H-25-287-287-130-FW-W | F8 | ePM1 75% | 287 × 287 × 130 | 3.2 | 750 | 140 |
| AR-F8-A-H-25-287-592-130-FW-W | F8 | ePM1 75% | 287 × 592 × 130 | 6.5 | 1,500 | 140 |
| AR-F8-A-H-25-490-592-130-FW-W | F8 | ePM1 75% | 490 × 592 × 130 | 10.7 | 2,500 | 140 |
| AR-F8-A-H-25-592-592-130-FW-W | F8 | ePM1 75% | 592 × 592 × 130 | 13 | 3,000 | 140 |
| AR-F9-A-H-25-287-287-130-FW-W | F9 | ePM1 85% | 287 × 287 × 130 | 3.2 | 750 | 160 |
| AR-F9-A-H-25-287-592-130-FW-W | F9 | ePM1 85% | 287 × 592 × 130 | 6.5 | 1,500 | 160 |
| AR-F9-A-H-25-490-592-130-FW-W | F9 | ePM1 85% | 490 × 592 × 130 | 10.7 | 2,500 | 160 |
| AR-F9-A-H-25-592-592-130-FW-W | F9 | ePM1 85% | 592 × 592 × 130 | 13 | 3,000 | 160 |
Comparison of 100 mm and 130 mm Models
| Comparison Criterion | 100 mm Model | 130 mm Model |
|---|---|---|
| Capacity code | M – Standard | H – High |
| Filtration area | 2.5–10 m² | 3.2–13 m² |
| Nominal airflow | 750–3,000 m³/h | 750–3,000 m³/h |
| Initial pressure drop | 100–170 Pa | 90–160 Pa |
| Main selection criterion | Limited filter depth | Larger filtration area and lower initial pressure drop |
Structural Components
Application Areas
Product Advantages
Filter Selection Criteria
- Nominal and actual system airflow
- Required ISO 16890 filter class
- Filter-housing width, height and depth
- Permitted initial and final pressure drop
- Required 100 or 130 mm depth
- Compatibility with 20 or 25 mm flange
- Gasket and compression system
- Airflow direction and surface-protection side
- Ambient temperature and relative humidity
- Dust concentration and particle characteristics
Inspection and Maintenance
The operating pressure drop should be monitored regularly with a differential pressure indicator or transmitter. Filter replacement should be determined by evaluating pressure drop, actual airflow, dust loading, operating time, hygiene requirements and the physical condition of the filter together.
Unless the technical documentation clearly states that the glass-fiber filter media is washable, it should not be cleaned with water or compressed air. Improper cleaning may damage the filter media, pleat geometry and perimeter sealing.
Frequently Asked Questions
Select the Right Rigid Filter for Your Project
Contact Airtes for Rigid Filter (Aluminum Frame) selection according to airflow, ISO 16890 class, filter dimensions, 100 or 130 mm depth, flange, surface protection and gasket options.