Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

UL 555 Fire Dampers

UL 555 Fire Dampers

FIRE SAFETY AND HVAC DUCT EQUIPMENT

UL 555 Fire Dampers

Fire Damper Solutions That Help Limit Fire Spread in HVAC Duct Systems

UL 555 fire dampers are duct-closing devices used to help limit the movement of flames and hot gases between fire compartments through HVAC ductwork.

During a fire event, the damper closes and isolates the duct opening. As a result, it helps limit fire spread through the ventilation system. Motorized, spring-return, fusible-link and automation-controlled configurations can be evaluated for project needs.

✆CONTACT US

UL 555 fire dampers for HVAC duct fire safety by Airtes Industrial

UL 555 Design Requirements

Project teams can evaluate suitable fire damper configurations against relevant UL 555 product and installation requirements.

Fire Isolation

The closed damper helps limit the movement of fire and hot gases through duct penetrations.

Automation Compatibility

The damper can work with a fire alarm system, building automation or a mechanical spring-return actuator.

What Are UL 555 Fire Dampers?

UL 555 fire dampers are duct-closing devices for HVAC systems. Engineers install them at fire-rated walls, shafts, floors and compartment penetrations. In a fire event, the damper closes and isolates the duct section.

Industrial plants, commercial buildings, hospitals, data centers, energy facilities and laboratories can use fire dampers to help limit fire spread through ventilation ducts. However, the selected damper, installation detail and rating must match the approved project design.

How UL 555 Fire Dampers Work

1

Normal Operation
The damper remains open and allows air to pass through the ventilation duct.

2

Fire Signal
A thermal element, fire alarm or automation signal starts the closing mechanism.

3

Blade Closure
A spring-return mechanism or motorized system moves the damper blade to the closed position.

4

Duct Isolation
The closed damper helps limit flame and hot-gas movement through the protected compartment opening.

Key Technical Features

Product Type: UL 555 fire damper configuration.
Purpose: Helps limit fire and hot-gas movement through the HVAC duct line.
Installation Area: Fire-rated walls, shafts, floors and duct penetrations.
Damper Type: Static or dynamic fire damper configurations can be selected according to the project.
Control Options: Fusible-link mechanism, spring-return actuator, motorized actuator or fire alarm integration.
Applications: HVAC ducts, fire-zone penetrations and critical mechanical service lines.

Technical Information

Item Description
Product name UL 555 fire damper
Reference standard UL 555 fire damper standard requirements
Primary duty Helps limit fire and hot-gas movement through an HVAC duct line
Operating position Open during normal operation and closed in a fire event
Closing method Thermal element, spring-return mechanism or motorized control
Control connection Fire alarm panel, BMS, automation or manual control option
Installation location Fire-rated walls, shafts, floors or duct penetration points
Casing construction Galvanized steel, stainless steel or sheet metal that matches the project specification
Blade construction Damper blade selected for the required fire-resistance duct-closing application
Accessories Limit switch, actuator, spring-return motor, thermal fuse and connection flange

Fire Damper Selection Table

Selection Item Selection Criterion Description
Damper size W × H or Ø dimension Defined according to the duct cross-section and project drawing.
Installation type Wall, floor, shaft or duct penetration Selected according to the fire-compartment penetration detail.
Damper type Static or dynamic Evaluated according to the fan operating scenario and duct pressure.
Closing method Fusible link, motorized or spring-return Defined by the fire alarm scenario and automation needs.
Accessories Limit switch, actuator or thermal element Selected for control, monitoring and building automation integration.

Materials and Casing Construction

The casing and blade construction of a UL 555 fire damper must suit the required HVAC duct application. Engineers can evaluate galvanized steel, stainless steel or other materials that match the approved project specification.

The damper blade, connection flanges, shaft-and-bearing system, closing mechanism and accessories must match the duct size, installation direction and fire scenario.

Installation Applications

Duct Penetration HVAC ductwork can use the damper at fire-zone penetration points.
Fire-Rated Wall The damper can serve as a duct-closing element at fire-rated wall penetrations.
Shaft Penetration Project teams can evaluate the damper for mechanical and ventilation shaft applications.
Floor Penetration The damper can support fire-compartment continuity at inter-floor duct penetrations.

Ordering Information

Order Parameter Required Information
Model UL 555 fire damper
Size Width × height or round duct diameter
Installation direction Horizontal, vertical, wall or floor application
Control type Fusible link, motorized, spring-return or automation controlled
Accessories Limit switch, thermal element, actuator, connection flange and control wiring

Applications

HVAC duct systems
Fire-compartment penetrations
Mechanical shaft applications
Commercial buildings and high-rise projects
Hospitals, hotels, malls and data centers
Industrial facility mechanical systems

Benefits of Use

Helps limit the movement of fire and hot gases through ductwork.
Supports the continuity of the fire compartment.
Adapts to different projects with motorized or mechanical closing options.
Can integrate with building automation and fire alarm scenarios.
Can be evaluated for wall, shaft, floor and duct penetrations.
Supports project specifications that require UL 555 fire damper configurations.

Get Information About UL 555 Fire Dampers

The selection of UL 555 fire dampers requires an evaluation of duct size, installation detail, fire compartment, damper type, control scenario, actuator selection, accessory needs and project specification.

Request a technical evaluation for UL 555 fire dampers and HVAC fire safety solutions.

✆CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Hard and Soft Water Systems: Water Softening Solutions
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information