Accurate Engineering Superior Performance
  • [email protected]
  • Pendik - İstanbul
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
AirTes Endüstriyel Klima Tesisat AirTes Endüstriyel Klima Tesisat
🇺🇸English
  • 🇹🇷Türkçe
  • 🇺🇸English
  • 🇸🇦العربية
  • 🇷🇺Русский
  • 🇩🇪Deutsch
    • Home page
    • Corporate
      • About Us
      • Our Certificates
      • Privacy Policy
    • Our Services
    • Products
      • Dust Collection Systems
      • Wet Filtration Systems
      • Explosion Protection and Fire Detection Systems
      • Extraction Equipment
      • Industrial Fans and Blowers
      • Industrial Filters
      • Humidity Control Systems
      • Cleanroom Systems
      • Explosion-Proof Heating and Cooling Systems
      • Ventilation Systems
      • Mechanical Installation Systems
      • Our Industrial Manufacturing
      • Air Measurement and Testing Instruments
      • Explosion-Proof Automation Systems
      • SolarWall – Solar Thermal Energy
    • Our Practices
    • Academy
    • Contact Us
    •   (0216) 606 25 38

Hard and Soft Water Systems: Water Softening Solutions

Hard and Soft Water Systems: Water Softening Solutions

AİRTES SERVICES

Hard and Soft Water Systems: Water Softening Solutions

Water softening systems are ion exchange units that remove hardness from water. The system swaps calcium and magnesium ions for the sodium ions held on the resin.

Once the resin capacity is used up, regeneration is carried out with brine. As a result, the unit returns to service and the cycle continues without interruption.

These units are used in both residential and industrial applications. In addition, they protect heat transfer in boilers, heat exchangers and cooling lines. Consequently, energy consumption and maintenance costs fall.

Water softening system - resin vessel and brine tank unit
H₂O

Hardness Analysis

Raw water hardness is measured. Unit capacity is then set according to daily consumption.

Ca

Cation Resin

The resin bed captures Ca and Mg ions. As a result, the outlet water is free of hardness.

Na

Salt and Regeneration

The NaCl solution in the brine tank recharges the resin. Moreover, the rinse water goes to drain.

⚙

Automatic Control Valve

Regeneration is triggered by volume or by time. Therefore no operator intervention is required.

Before Water Softening: How Is Hardness Measured?

Raw water hardness must be known before the right unit can be selected. Hardness is expressed in several different units. Therefore it is important to check which unit a figure refers to.

French Degrees (°fH)
The most common unit in Türkiye. One °fH corresponds to roughly 10 mg/L CaCO₃.
German Degrees (°dH)
Found on equipment of European origin. One °dH equals about 1.78 °fH.
ppm / mg/L CaCO₃
Used in laboratory analysis reports. It suits international comparison well.
Hardness Classes
Up to 6 °fH is soft, 6-12 °fH moderately hard, 12-18 °fH hard and above 18 °fH very hard.

What Are Hard and Soft Water?

Hard water contains a high concentration of dissolved calcium and magnesium. Pure water is naturally soft. However, water picks up these minerals as it passes through rocks such as limestone.

The Ca and Mg ions in water are the true source of scale. These ions precipitate under heat and leave a solid layer on the surface. Therefore removing hardness matters for the service life of the installation.

How Does Water Softening Work?

Hardness removal takes place in units built around a cation resin. Ion exchange occurs as raw water passes through the resin bed. The sodium on the resin swaps places with the calcium and magnesium in the water.

Over time the sodium on the resin is depleted. At that point the unit regenerates with a salt (NaCl) solution. As a result, the resin recovers its capacity and the cycle starts again.

Raw water must not reach the outlet during regeneration. Therefore plants running without interruption prefer a twin-tank system. In this way one tank keeps working while the other regenerates.

Effects of Hard Water on Plant and Equipment

Hard water leaves scale on every surface it heats. This layer narrows the pipe bore and reduces flow. In addition, it disrupts heat transfer in boilers and heat exchangers.

When heat transfer drops, the equipment spends more energy for the same result. Consequently, fuel and electricity consumption rise. Besides that, components such as heating elements and coils wear out sooner.

Together with soap, hard water forms a thin film on surfaces. Therefore stains remain and detergent consumption increases. On the health side, the World Health Organization has not set a health-based guideline value for hardness in its drinking water guidelines. Softening is applied primarily for equipment life and energy efficiency.

Flow Controlled Water Softening Units

Flow controlled units count the treated volume and decide when to regenerate. Capacity is calculated from the raw water hardness and the resin quantity. As a result, only the necessary amount of salt is consumed.

Time controlled models instead regenerate at a preset hour. However, this method can waste salt when consumption is irregular. Therefore plants with a variable draw-off prefer flow controlled units.

What Damage Does Hard, Scaling Water Cause?

  • Equipment running on hard water has a shorter service life.
  • Heating elements become coated with scale and lose efficiency.
  • Heat transfer is impeded, so equipment heats up slowly and energy is wasted.
  • Scale marks remain on every surface the water touches.
  • Hard water lathers poorly, so soap and detergent consumption rises.
  • Mineral residue builds up in laundered textiles and fabric looks dull.
  • Soap residue and film make surfaces harder to clean.
  • Scale accumulates in PVC and metal pipes and restricts flow.
  • Shower heads, tap aerators and valves become blocked.
  • Solar collectors and calorifiers lose efficiency.

With over 10 years of experience, we engineer hard and soft water systems with a specialist team that follows the technology closely. We analyse the hardness at every site, then install the solution that matches the required capacity.

Request Information on Water Softening Systems

If you would like information about our hard and soft water systems, please contact us. You can send your water analysis result and daily consumption by phone on +90 216 606 25 38 or by e-mail to [email protected].


CONTACT US

Our Other Services

Fire Suppression Systems

Thermal Oil and Superheated Water Systems

Infrastructure Installation

Plumbing Installation Services

Industrial Water Treatment Systems

Medical Gas Installation

industrial equipment manufacturing

Natural Gas Installation

Design and Contracting

Consulting Services

  • Our Services
    • Fire Suppression Systems
    • Thermal Oil and Superheated Water Systems
    • Infrastructure Installation
    • Plumbing Installation Services
    • Industrial Water Treatment Systems
    • Medical Gas Installation
    • industrial equipment manufacturing
    • Natural Gas Installation
    • Design and Contracting
    • Consulting Services
    • Heating and Cooling Systems
    • Steam & Condensate Installation and Boiler Systems
    • Compressed Air Systems
    • Industrial Air Conditioning Systems
    • ATEX Dust Collection Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • Industrial Plant Installation and Relocation Services
    • Ventilation Systems
    • mechanical installation services
    • Cleanroom Validation Services
    • Industrial Insulation and Cladding Services
    • Technical Maintenance and Repair Services
    • Automation Engineering and Implementation Services
    • Electrical Engineering and Installation Services
    • Solar Energy and Energy Efficiency Systems
How can we help you?

You can reach us from the [email protected] e-mail address or by calling (0216) 606 25 38.

Call Us
Quick Menu
    • Home Page
    • Corporate
    • Our Services
    • Our Practices
    • Contact Us
Our Services
    • Airport HVAC Solutions
    • Industrial Air Conditioning Systems
    • Dehumidification and Humidification Systems
    • Clean Room Systems
    • ATEX Dust Collection Systems
Our Practice
  • APPLICATION AREA Food Production Facility HVAC Solutions
  • Chemical Industry HVAC Solutions
  • Defense Industry HVAC Solutions
  • Wood and Paper Industry HVAC Solutions
  • Cleanroom HVAC Solutions
Contact Us

Address: Merkez Ofis: Güzelyalı Mah. Yanyol cad No:3/2 Pendik/İstanbul Depo Ofis: Fevzi Çakmak Mah. Dilbeste Sok. No:6/9 Pendik/ İstanbul
Phone: (0216) 606 25 38
Mobile: (0537) 797 38 38
Mail: [email protected]

© 2026 Air-Tes Industrial Air Conditioner Installation All Rights Reserved.

Web Designİstanbul Web Tasarım Ajansı - Penta YazılımPenta Yazılım profesyonel web tasarım ajansı logosu Penta Yazılım animasyonlu marka simgesi
yukaricik
(0216) 606 25 38 I Want information